wise until the central plate [1-12] rests against
the bottom of the machine.
Purge position is reached.
Press the start button [1-1] and hold > 1 s.
The purging preparation symbol appears on the
display [1-20] . The process starts after 1 s.
Continue purging until new adhesive appears in
the adhesive nozzle [1-14].
Adhesive nozzles are open, pressure has built in
the adhesive cartridges.
The purging symbol appears on the display [1-
20]
together with a status indicator.
Interrupt purging: press the start button [1-1]
again.
Adhesive nozzles are open, pressure stops
building in the adhesive cartridges.
Stop purging and leave purging position: turn
the rotary knob for adjusting the edge height [1-
4] clockwise.
Central plate moves upwards, adhesive nozzles
are closed, pressure stops building in adhesive
WARNING
Any maintenance or repair work that requires
opening of the motor or gear housing should only
be carried out by an authorised Customer Service
Centre (name supplied by your dealer)!
Maintenance or repair work carried out by an
unauthorised person can lead to the wrong con-
nection of the power cord or other components,
which in turn can lead to accidents with serious
consequences.
WARNING
To prevent accidents, always remove the plug
from the power supply socket before carrying out
any maintenance or repair work on the tool!
Do not use compressed air to clean the electrical
tool! Do not try to clean parts inside the tool in
this way, as you could let foreign objects in
through the openings of the tool housing.
16
cartridges. Display [1-20] indicates normal
standby status.
Insert the drop catcher [1-13] again.
Switch off the machine and allow to cool.
If necessary, clean the adhesive nozzle [1-14]
carefully using a strip of wood. Do not use me-
tallic or highly flammable materials!
Remove the drip catcher [1-13] and turn upside
down to clean.
Observe the following instructions:
– Allow the machine to cool completely before
placing in a Systainer.
– Do not transport the machine in purging mode
otherwise adhesive may escape.
Service and maintenance
Certain cleaning agents and solvents are harmful
to plastic parts.
Some of these include, but are not limited to:
Gasoline, Acetone, Methyl Ethyl Ketone (MEK),
Carbonyl Chloride, cleaning solutions containing
Chlorine, Ammonia, and household cleaners
containing Ammonia.
Always keep the machine clean. Read chapter
Purging of adhesive cartridges and After fin-
ishing work!
If the plastic sliding plate [2-1] (wear part) is
damaged, the plate can be replaced by loosen-
ing the 4 screws underneath the support base
[1-17].
Keep the ventilation slits on the electric power
tool clean and unobstructed to guarantee ade-
quate cooling.
Store in a cool location that is free of dust.
After finishing work
CAUTION