4.2.2 Size of Mounting Plate
Front mounting bracket
4.3 Installation Steps
4.3.1 Preparation before Main Machine Installation
a) Before installing the door opener, please confirm that the door were installed correctly, please
ensure that the door can be manually operated smoothly, and the door limit stopper can effectively
prevent the door to continue moving.
b) Please keep a distance of 40-50mm between the door bottom and the ground for installing
the electric lock. If electric lock is not required, the distance between the door bottom and the ground
should be ≥20mm.
c) The recommended mounting height of the 2 main machines is around 300 ~ 800mm above the
ground, and make sure there are reliable fixed points for mounting brackets.
Cable bury.
In order to ensure the normal operation of the door opener and protect the cable from damage,
please use two PVC pipes to bury the motor and power cables, and the control cables separately. One
PVC pipe for motor and power cables, the other one for control cables.
Mounting brackets fixing
In order to install the main machines firmly, it is recommended to use the expansion screws to
fix the mounting brackets.
4.3.2 Accessory Installation
a) Before installing the main machines, please install the wall bracket on the wall first, then fix
EN
Wall bracket
Figure 3