the connecting bracket, finally install the front mounting bracket on the door.
Note: Please detect by gradient before fixing to ensure that the front mounting bracket and
the connecting bracket are in the same level.
1 – Hexagon screw; 2 – Expansion screw; 3 – Nut; 4 – Nylon gasket
b) The connecting bracket and the wall bracket can be connected according to different conditions,
please refer to figure 5.
c) Users should prepare power cables for the control box and the main machines by themselves due
to the different installation environment. The cores for the control box power supply cable should be
more than 3, the cores for the motor cable are 2. If users need to install external accessories like
electric lock, infrared sensor, alarm lamp, external button switch etc., please increase the embedded
cables accordingly, please make sure the sectional diameter of electric lock cable is over 1.5mm²,
sectional diameter of other cables is over 0.5mm². The cable length should be determined by users
according to their installation situations.
Note: The outlet on the PVC pipe should be downward in order to avoid the rainwater flowing into
the pipe along the cable.
d) Before the installation, please unlock the two main machines. Unlock method: Remove the cover,
insert the manual release bar, rotate the bar until it's released, as shown in Figure 6, then turn the
telescopic arm, you'll find it is stretched easily.
EN
Figure 4
Figure 5