The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
Install the device on a plane surface.
Connect the fixture to the mains with the power-plug.
With the POWER-switch, you can switch the device on and off , and the B-10 LED starts running. The LEDs
begin to burn and the ball starts rotating.
CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Rotation-speed:
Maximum ambient temperature T
Maximum housing temperature T
Min. distance from flammable surfaces:
Min. distance to lighted object:
Number of LEDs:
Dimensions (LxWxH):
Weight:
Please note: Every information is subject to change without prior notice. 19.02.2009 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
:
a
(steady state):
B
230 V AC, 50 Hz ~
11 W
circa 6 RPM
45° C
45° C
0.5 m
0.1 m
1 x 3W
195 x 195 x 175 mm
1.5 kg
11/20
00040973.DOC, Version 1.1