11-OPERATION
11.5 TROUBLE SHOOTING
SITUATION
The voltage lamp does not light up after
turning the mainswitch on ON,
The vacuum plate does not move.
The vacuum pump does not work.
The motors don't come on after pressing
the VACUUM PUMP button.
The vacuum cups do not grab the case.
The vacuum plate hits against the case
magazine.
The box is not opened by the vacuum plate
When retracting, the vacuum plate does not
stop in line with the driving belts.
The machine stops without pushing the box
in the driving belts and the box falls down.
CE-10
11-USO DE LA MÁQUINA
CAUSE
EMERGENCY STOP button pressed.
Safety door not latched
Insufficient air pressure.
The vacuum plate is not in position.
Solenoid valve N. 3.
Thermal switch N.12
Thermal switchN. 11
Adjustment of height of case magazine.
Speed of vacuum plate
Vacuum pump.
Sensor N. 2
Excessive distance between the sensor
and the vacuum plate
Case squaring cylinder in wrong position.
The return speed of the case opener is too
slow.
Too high speed of the carriage.
Sensor N. 1
Wrong position of the sensor which
regulates the position of the slider
vacuum cylinder.
Uncorrect calibration of the sensor of the
vacuum pump.
62
SOLUTION
Check.
Check.
Adjust work to 6÷7 BAR
Press blue RESET button
Check
Repair
Repair
Adj u st
Adj u st
Check
Check
Decrease the distance between them.
Adjust the position of the cases in the case
magazine.
Slightly increase the return speed of the
vacuum plate.
Decrease the speed acting on the does
regulator.
Adjust the distance between the sensor and the
vacuum plate cylinder.
Adjust the position of the slider
extended proximity switch.
Adjust the sensitivity of the sensor.
JULY 2004