5 Installation
5.9
Positioning the ceiling floor unit
5.9.1
Installation location
Fig.190
Floor installation
500
Fig.191
Ceiling installation
20
3000
500
5.9.2
Accessing the hanger
Fig.192
1
3
164
When choosing the installation location, take into account the minimum
space requirements as described in the figures.
500
Select a suitable position in order to achieve a uniform air temperature
in the place of installation.
Make sure that the indoor unit is far enough from the food preparation
equipment to ensure that products are not attracted into the ceiling floor
unit
MW-6070072-01
500
MW-6070074-01
1. Slide the suction grid fixing knobs backwards to open the inlet grid.
2. Hold the knob at the back of the intet grid and pull the suction grid
forward to remove.
3. Unscrew in the bottom cover as shown. Remove the end cap by
pulling up.