Check
Gun and Nozzle
Extension
Examine the hose connection to the spray gun and make
sure it is secure. Test the trigger by pressing it and making
sure it "springs back" into place when you release it Put
the safety latch in the ON position and test the trigger. You
should not be able to press the trigger.
Check
In-Line
Filter
Refer to Figure 21 and service the in-linefilter if it
becomes clogged, as follows:
I.
2.
.
Filter Screen
Nozzle Extension
_
_c_._f_
O-ring _'_
Detach spray gun and nozzle extension from high
pressure hose. Detach nozzle extension from spray
gun and remove o-ring and screen from nozzle
extension. Flush the screen, spray gun, and adjustable
nozzle extension with clean water to clear debris.
if the screen is damaged, the o-ring kit contains a
replacement in-line filter screen and an o-ring. If
undamaged, reuse screen.
Placethe in-line filter screen into the threaded end of
the nozzle extension. Direction does not matter. Push
the screen in with the eraser end of a pencil until it
rests fiat at the bottom of the opening. Take care to
not bend the screen.
4.
Placethe o-ring into the recess. Pushthe o-ring snugly
against the in-line filter screen.
5.
Assemble the nozzle extension to the spray gun, as
described earlier in this manual.
Purge Pump of Air and
Contaminants
To remove air from the pump, follow these steps:
• Set up the pressure washer as described in "Preparing
Pressure Washer For Use". Connect the water supply
and turn water on.
• Pull the trigger on the spray gun and hold.
• When the water supply is steady and constant, engage
the safety latch.
To remove contaminants from the pump, follow
these steps:
• Set up the pressure washer as described in "Preparing
Pressure Washer For Use". Connect the water supply
and turn water on.
• Start the engine according to instructions in "To Start
Your Pressure Washer".
• Remove nozzle extension from spray gun.
• Squeezethe trigger on the spray gun and hold.
• When the water supply is steady and constant, engage
the safety latch and attach the nozzle extension.
Nozzle
Maintenance
if a nozzle becomes restricted or clogged with foreign
materials, such as dirt, excessive pump pressure may
develop. A pulsing sensation occurs during use. This
generally is not a pump related problem, but rather a
clogged or partially restricted nozzle.
If a nozzle become clogged or partially restricted,
immediately clean it with the kit included with your
pressure washer by following these instructions:
• Shut off the engine and turn off the water supply.
• Remove the nozzle from the end of the nozzle extension.
• Use the wire includedin the kit or a small paper clip to
free the foreign materials clogging or restricting the
nozzle (Figure 22).
to remove
debris.
• Remove additional debris by rinsing out the nozzle. Rinse
between 30 to 60 seconds.
• Reinstall the nozzle into the nozzle extension.
• Reconnect the water supply,turn on the water, and start
the engine.
• Test the pressure washer.
/
13