Descargar Imprimir esta página

Abicor Binzel xFUME ABIROB W Manual De Instrucciones página 31

Antorcha con extracción de humos

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
®
®
xFUME
ABIROB
W
3
Product description
3.1
Technical data
Tab. 1
General torch data (EN 60974-7)
Transport and storage
Relative humidity
Operating temperature
Type of use
Polarity of the electrodes for DC
Tab. 2
Product-specific torch data (EN 60974-7 and EN ISO 21904-1)
Type
Type of
Load
cooling
DC
CO
2
A
®
®
xFUME
ABIROB
W
W500
Liquid
550
The degree to which welding fumes are captured during torch-integrated
extraction depends on many factors, such as the position of the suction
nozzle, the welding geometry, and the rate of smoke emission during
Tab. 3
Liquid cooling specifications/cable assembly specifications
Cooling data
Supply temperature
Flow
Flow pressure
Coolant connection
Cooling device output
3.2
Figures used
All figures can be found at the start of this document.
4
Commissioning
WARNING
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► The provided fume extraction system must be used when operating the device.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner or a damp cloth.
► Do not use the device with a disconnected nozzle for shielding gas and suction.
WARNING
Electric shock due to damaged or improperly installed components
Damaged or improperly installed components may result in potentially fatal electric shocks. Components include: welding torch, cable assembly, spare parts,
wear parts.
► Inspect all components prior to each use and check that all connections are duly installed and undamaged.
► Clean soiled components immediately.
► Replace damaged components immediately.
► Damaged, deformed or worn components must only be replaced by an electrician who has been trained by ABICOR BINZEL.
Perform the following tasks before each use:
1 Switch off the power source and unplug the power plug.
2 Close off the gas supply.
3 Switch off the coolant circuit (optional).
−25°C to +55°C
Shielding gas (DIN EN ISO 14175)
Up to 90% at 20°C
Voltage rating
−10°C to +40°C
Protection type of the device
connections (EN 60529)
Automatic
Type of voltage
Usually positive
DC
Wire Ø
Gas flow rate
M21
A
%
mm
500
100
0.8–1.6
Approx. 20
Max. 50°C
Min. 1.0 l/min
Min. 1.5 bar/max. 3.5 bar
Plug-in nipple with DN 5
Min. 800 W
Volume flow
For induced speed 0.35 m/s
Suction nozzle
3
l/min
m
/h
59
the welding process. Under optimal conditions, over 95% of the welding
fumes can be captured in accordance with ISO 21904-3.
Cable assembly specifications
Standard length hybrid
Standard length power/
water cable
Control lead
Power range hybrid
Power range power/water
cable
4 Check, clean, and if necessary, replace the welding torch.
5 Check, clean, and if necessary, replace spare and wear parts.
6 Check, clean, and if necessary, replace the cable assembly.
3 Product description
CO
and mixed gases M21
2
Peak value of 141 V
IP3X
DC
Required vacuum
at the connector
Connector
3
m
/h
kPa
108
7.4
1.35 m
1.35 m
7 × 0.25 mm
Max. 500 A
Max. 750 A