recommended that the filter cartridges be replaced
every 6-12 months, or when there is a noticeable
change in taste, odor, or flow of filtered water.
Ensure the correct cartridge set is purchased for
the system.
Model F2000-B2B and F2000-B2M use F2B2-RC2 Replacement
Cartridge set.
8. Cartridge Replacement
A. Relieve pressure by turning off the water supply to the system
and opening a faucet until water flow stops. Place a bucket or
towel under the system to catch any water drips (Figure 8a).
B. Remove the cover and lift the locking bar upward until the filter
cartridge disengages from the filter head assembly (Figure 8b).
C. Pull the cartridge away from the filter head assembly (Figure
8c).
D. Ensure the locking bar is fully in the up position (Figure 8c).
E. Align the posts on the filter cartridge with the ports in the filter
head assembly. Slide the cartridge filter towards into the filter
head assembly engaging with the locking bar causing it to drop
forward and down. (Figure 8d).
F. Pull down the locking bar until it snaps into place
(Figure 8e).
G. Install cover.
NOTE: See Placing the System into Operation section for
remaining steps.
TROUBLESHOOTING
Leaks between filter head assembly and filter
cartridge
1. Relieve pressure by turning off the water supply to the system
and opening faucet until water flow stops. Place a bucket or
towel under the system to catch any water drips.
2. Remove cartridge and inspect O-rings to make sure they are
seated and clean.
3. Install filter cartridge. Place system into operation and check
for leaks. If leaks persist, turn off the water supply and contact
Technical Support at 1-800-279-9404.
Leaks from tubing fittings
1. Relieve pressure by turning off the water supply to the system
and opening faucet until water flow stops. Place a bucket or
towel under the system to catch any water drips.
2. Depress collet on system or inlet supply adapter tubing fittings
and pull tubing from fitting. Inspect surface of tubing for
scratches or debris. Clean or cut back tubing to access clean
surface.
3. Wet the end of the inlet tubing and press into the inlet fitting
of the system. Ensure the tubing is fully pushed past the fitting
O-rings. Place system into operation and check for leaks. If
leaks persist, turn off the water supply and contact Technical
Support at 1-800-279-9404.
8a
8b
8d
FRESHPOINT F2000-B2B, F2000-B2M Filtration Systems Instruction Manual • 7
262.634.2386 | greatlakesintl.com
8c
8e

Publicidad

loading

Este manual también es adecuado para:

Freshpoint f2000-b2m