Descargar Imprimir esta página

GRE VSG75 Manual De Instrucciones página 12

Bomba de velocidad variable para piscina

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
1.2 - The default speeds can not be changed. However, you can adjust to a temporary pump speed within a
default settings with the "UP" or "DOWN" buttons.
1.3 - Once you have the temporary speed set as desired press the "SET" button to adjust to next default speed.
1.4 - In Manual mode, if you turn off the pump, the current speed can be auto-saved when you use the pump
next time.
2.0 - AUTOMATIC OPERATING MODE: To start Automatic Mode Programing press "SET" once (See Image #2).
NOTE - Automatic Mode will not function until Current Time and Times & Speeds Parameters are programed.
Follow the instructions below to program Current Time and the Times & Speeds Parameters for each segment.
(Image #2)
2.1 - Program Current Time:
• To set Current Time press the "RUN/STOP" and "SET" button at the same time, hold for 3 seconds. The hour
setting will flash. Use the UP or Down buttoms to adjust to current hour. When you have the hour correct press
the "SET" button once to move to minute setting. The minute setting will flash. Press the "UP" or "DOWN" but-
ton to adjust to the current minute.
2.2 - Program "T" Segment Times and Operating Speeds:
• A maximum of 4 timing segments can be programmed. Each timing segment includes three parameters: "Start
Time", "End Time" and "Running Speed". The segments are shown on the screen as "T1", "T2", "T3" & "T4".
After setting, the pump runs at the speed programmed within the times set for Start and End. Times and speeds
are saved when power is off.
• When programming times and speeds parameters for the first time, programming automatically starts with
the first time and speed segment, "T1".
• When programming a time and speed segment, all parameters (Start Time, End Time and Running Speed) are
displayed. The parameter being programmed flashes.
• Press the "SET" button to start programming your "T1" operating time and speed segment. Use the "UP"
or "DOWN" buttons to program the Start Time, End Time and Operating Speed. The parameter being set will
flash. When you have the times or speed set as you want, press "SET" to save it. The next parameter will flash.
Continue through the Start Time, End Time and Speed settings until finished. Once you have the first segment
programmed press the "SET" buttom for 3 seconds to save and exit that segment.
• Press the "DOWN" buttom to move to the "T2" segment you wish to program. Repete the process used to
program the 1st time and speed segment.
• Continue the process through "T3" & "T4" until you have programmed as many of the four available time and
speed segments you wish. It is not necessary to program all four of the time and speed segments.
• If you make a mistake while you are programming time and speed in a segment you can go back by pressing
"SET" once. Then switch to the time or speed setting you want to change by presssing "SET" until that setting
flashes. Use the "UP" or "DOWN" buttons to change the setting.
• If during the process of programming a "T" segment you fail to press a button and more than 8 seconds elaps-
es, the programming for that "T" segment will automatically save and exit. You can cycle back to that segment
12
Instruction manual
- VARIABLE SPEED SWIMMING POOL PUMP

Publicidad

loading