Operating Instructions
Safety Switch TX...AS1
The AS-Interface output must be switched on
f
with D0  =  1 so that the guard locking solenoid
can be released by the second safety output of
the monitor.
Status signals (not relevant to safety)
The state of the AS-Interface input bits D0 and D1 for
door monitoring and the AS-Interface input bits D2
and D3 for solenoid monitoring can also be polled
by the control system (PLC) (refer to the operating
instructions for the AS-Interface safety monitor).
LED displays
The AS-Interface bus status is indicated by two LEDs
(Power, Fault).
Two additional LEDs can be connected via the
AS-Interface bus, e.g. to indicate the status signals
(see status signals and technical data).
Function test
WARNING
Fatal injury due to faults during the function test.
Before carrying out the function test, make sure
f
that there are no persons in the danger area.
Observe the valid accident prevention regula-
f
tions.
Check the device for correct function after installa-
tion and after every fault.
Proceed as follows:
Mechanical function test
The actuator must slide easily into the actuating
head. Close the guard several times to check the
function. The function of any manual releases (except
for the auxiliary release) must also be tested.
Electrical function test
1. Switch on operating voltage.
2. Close all guards and activate guard locking.
The machine must not start automatically.
¨
It must not be possible to open the guard.
¨
3. Start the machine function.
It must not be possible to release guard locking
¨
as long as the dangerous machine function is
active.
4. Stop the machine function and release guard
locking.
The guard must remain locked until there is no
¨
longer any risk of injury (e.g. due to movements
with overtravel).
It must not be possible to start the machine
¨
function as long as guard locking is released.
Repeat steps 2 - 4 for each guard.
Inspection and service
WARNING
Danger of severe injuries due to the loss of the
safety function.
If damage or wear is found, the complete switch
f
and actuator assembly must be replaced. Re-
placement of individual parts or assemblies is
not permitted.
Check the device for proper function at regular
f
intervals and after every fault. For informa-
tion about possible time intervals, refer to
EN ISO 14119:2013, section 8.2.
Inspection of the following is necessary to ensure
trouble-free long-term operation:
Correct switching function
f
Secure mounting of all components
f
Damage, heavy contamination, dirt and wear
f
Sealing of cable entry
f
Loose cable connections or plug connectors.
f
Info: The year of manufacture can be seen in the
bottom right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety regula-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
This device is intended to be used with a Class 2
power source in accordance with UL1310.
As an alternative an LV/C (Limited Voltage/Current)
power source with the following properties can be
used:
This device shall be used with a suitable isolating
f
source in conjunction with a fuse in accordance
with UL248. The fuse shall be rated max. 3 A and
be installed in the max. 33.3 V DC power supply
to the device in order to limit the available current
to comply with the UL requirements
Please note possibly lower connection ratings for
your device (refer to the technical data). A maximum
power value of 100  VA according to Tab. 32.1
(UL508) must not be exceeded.
1) Note on the scope of the UL approval:
The devices have been tested as per the requirements of UL508
and CSA/C22.2 no. 14 (protection against electric shock and
fire).
Declaration of conformity
The EU declaration of conformity can be found at
www.euchner.com. Enter the order number of your
device in the search box. The document is available
under Downloads.
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Germany
Service telephone:
+49 711 7597-500
E‑mail:
support@euchner.de
Internet:
www.euchner.com
8
Technical data
Parameter
Housing material
Degree of protection
Mechanical life
Ambient temperature
Degree of contamination
(external, acc. to EN 60947-1)
Installation position
Approach speed, max.
Extraction force (not locked)
Retention force
Actuating force, max.
Actuation frequency
Switching principle SK, ÜK
Contact material
Connection
Weight
.
 1)
Locking force F
max
Locking force F
acc. to
Zh
EN ISO 14119
Guard locking solenoid
Solenoid operating voltage
(auxiliary voltage on black
AS-Interface cable)
Solenoid operating current
Duty cycle
Connection
AS‑Interface data acc. to
AS-Interface specification 2.1
Operating voltage, AS-Interface DC 22.5 ... 31.6 V
Total current consumption,
max.
Valid AS-Interface addresses
AS‑Interface inputs
Door monitoring contact SK
Solenoid monitoring contact
ÜK
AS‑Interface outputs
D0
D1
D2
AS-Interface Power LED
AS-Interface Fault LED
Characteristics acc. to EN ISO 13849‑1
Monitoring of guard locking and the guard position
B
10D
Value
Die-cast alloy, cathodically dipped
IP67, mating connector inserted
1 x 10
operating cycles
6
-20 ... +50 °C
3 (industrial)
Any
20 m/min
35 N
20 N
35 N
1,200/h
Positively driven, slow-action
switching contact
Silver alloy, gold flashed
Plug connector M12, 4-pin
Approx. 0.8 kg
1,700 N
F
max
(F
=
) = 1,300 N
Zh
1.3
DC 24 V +10%/-15% 8 W
Power supply unit with electrical
isolation (IEC 60742, PELV)
300 mA
100%
M12 plug connector
EA code: 7
ID code: B
45 mA
1 - 31
Acc. to AS-Interface Safety at
Work
D0, D1
D2, D3
Guard locking solenoid,
1 = solenoid energized
Red LED, 1 = LED on
Green LED, 1 = LED on
Green, AS-Interface power on
Red, offline phase or address 0
5 x 10
6