Filter management
The capacity is set based on the quantity of water processed and the time past (365 days).
When the filter runs out, the icon (9) will be flashing. To reset, switch the machine off and on, keeping key R (14) pressed. The machine will respond with three
consecutive beeps.
Key R (14) is also used to display certain parameters of the equipment. In particular, if pressed during the machine on status, the following will be displayed in sequence:
filter flow rate, LCD board firmware version, power board firmware version.
(7) DIP SWITCH LCD BOARD
0
Dip switch 1
15 minute block
Dip switch 2
No filter alarm block
Dip switch 3
Manage filter
Dip switch 4
365 days filter
Dip switch 5
See FILTER table
Dip switch 6
See FILTER table
TABLE OF ALARMS
NAME
LCD
Litres filter alarm
Filter icon, L, zero flashing
Time filter alarm
Filter icon, Clock zero flashing
Flooding
"Flood" displayed
15 minutes lock
Err15 flashing
Pressure adjustment VR20
The pump is equipped with a pressure adjustment system. In the pressure testing phase it is adjusted to 7.5 bar. The pressure can vary based on the actual conditions
at the installation site or based on system wear. After installation and during the maintenance phase, check and adjust the pressure if necessary.
Vessel pressure adjustment VR23
To adjust the pressure, do not work on the pump head, but on the vessel adjustment device.
Procedure
Mount a pressure gauge between the motor pump and the vessel, put the system into operation and check the pressure. If calibration is necessary, proceed as follows:
• Unscrew the adjustment device to minimum pressure
• Screw in the adjustment device to slightly exceed the calibration pressure
• Work on the adjustment device to reach the calibration pressure
PERMITTED VALUES
Sensor
6.5 Bar
Optimal
7.5 Bar
Maximum
8 Bar
Bypass adjustment
The pump is equipped with a bypass system to adjust the TDS (Total Dissolved Solids) of the produced water; the bypass is
completely tightened in the test phase. After installation and in the maintenance phase, check and adjust the bypass if necessary.
The TDS (Total Dissolved Solids) can be estimated with the TDS meter or conductivity meter. Use the bypass system knob until
you reach the desired value.
TDS (Total Dissolved Solids) that is too low could influence the pH. After adjustment, measure the pH, checking it has returned
within the potability values.
16
FILTER
1
DIP 5
No 15 minute block
0
Filter alarm block
1
DO NOT Manage Filter
0
1
183 days filter
See FILTER table
See FILTER table
BACKLIGHT
Red
Red
Red
Red
DIP 6
0
21.000 L
0
12.000 L
1
500.000 L
1
6.200 L
RESET
Reset procedure
Reset procedure
(switch off, check the machine and switch on)
(press R key>3" or switch off and on)