GB
4.1
Fitting the scarifier (04 - 06)
Installing the lower handlebar (04)
1. Insert the lower handlebar (04/1) into the
openings (04/2) in the scarifier (04/a).
2. Secure the lower handlebar by tightening the
screws (02/14, 03/13, 04/3) for the lower han-
dlebar finger-tight (04/b).
Fitting the cable strain relief hook (05)
1. Thread the cable strain relief hook (05/1) on-
to the upper handlebar from below (05/a).
2. Attach the cable strain relief clip (05/2) below
the cable strain relief hook on the upper han-
dlebar (05/b).
Installing the intermediate brace on the lower
handlebar (06)
1. Position the two intermediate braces (06/1)
on the lower handlebar (06/2).
2. Push the screws (06/3) through.
3. On the left-hand side: Push screw (06/3)
through cable clip (06/8) on the cable.
4. Fit the washers (06/4), nuts (06/5) and wing
nuts (06/6) and tighten.
Installing the upper handlebar on the
intermediate brace (06)
NOTE Fit the cable strain relief hook before
installing the upper handlebar.
1. Position the upper handlebar (06/7) on the in-
termediate brace (06/1).
2. Push the screws (06/3) through.
3. Fit the washers (06/4), nuts (06/5) and wing
nuts (06/6) and tighten.
Fitting the cable clips (06)
1. Fix the cable to the handlebar (06/e) with ca-
ble clips (06/9).
4.2
Installing the grass collector (07, 08)
See figures (07) to (08).
5 START-UP
IMPORTANT! Risk of damage to the appli-
ance. The aerator roller screw is fastened to the
underside of the scarifier.
■
Remove the aerator roller before switching
on the appliance.
26
5.1
Carrying out visual inspection
1. Check the appliance for damage and loose
screws. Replace the defective appliance
parts and tighten the screws.
2. Check the mains cable for damage. Replace
the defective mains cable.
3. Check the appliance for coarse soiling. Re-
move soiling.
5.2
Providing the mains cable and checking
the mains connection
Observe the safety instructions for the mains ca-
ble.
Demands on the mains cable
Obtain a mains cable that satisfies the following
requirements:
■
3 conductors with a minimum cross-section
of 2.5 mm (i.e. with protective conductor)
■
Maximum length 40 m
■
Spray water protected (protection category
IP44)
■
Suitable for outdoor use (H05RN-F quality,
i.e. rubber sheathed cable)
Demands on the mains connection
Check that the mains connection satisfies the fol-
lowing requirements:
■
Min. 10 A fuse
■
Fault current circuit breaker with max. 30 mA
trigger current
5.3
Adjusting the handlebar (06)
1. On both sides of the upper and lower handle-
bar at the intermediate brace:
■
Loosen the wing nut (06/6) at the inter-
mediate brace (06/1).
■
Remove nut (06/5) and washer (06/4)
from the screw.
■
Pull out (06/c) the screw (06/3).
2. On the left-hand side: Pull out screw (06/3)
with cable clip (06/8) on the cable.
3. Move the handlebar (06/2, 06/7) to the next
hole in the intermediate brace (06/d).
4. Tighten the handlebar again in the reverse
order.
32.4 E Basic Care | 38.4 E Combi Care