Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper
leveling for the plate to be fixed against the wall, then temporarily
fasten the plate with one steel nail.
2.Make sure once more the proper level of the plate, by hanging a
thread with a weight from the central top of the plate, then fasten
securely the plate with the attachment steel nail.
3.Find the wall hole location A/C using a measuring tape.
B=Ø60mm
EN
A=183.5mm
B=Ø60mm
A=195mm
B=Ø60mm
A=222mm
A=210mm
B=Ø60mm
D=31mm
When the mounting plate is fixed side bar and lintel
●Fix to side bar and lintel a mounting bar, Which is separately sold,
and then fasten the plate to the fixed mounting bar.
●Refer to the previous article, " When the mounting plate is first
fixed ", for the position of wall hole.
2
Making a Hole on the Wall and Fitting the Piping Hole Cover
●Make a hole of 60 mm in diameter, slightly descending to outside
the wall.
●Install piping hole cover and seal it off with putty after installation
Indoor side
(Section of wall hole)
Installation of the Indoor Unit
3
[Rear piping]
●Draw pipes and the drain hose, then fasten them with the
adhesive tape.
11
Indoor Unit Installation
AS25PBPHRA*
AS35PBPHRA*
AS25RBAHRA*
B=Ø60mm
AS35RBAHRA*
AS25PBAHRA*
35P
AS35PBAHRA*
C=113mm
AS25PCHHRA*
AS35PCHHRA*
AS50RCBHRA*
B=Ø60mm
40P
C=126mm
AS50PDHHRA*
AS50PDPHRA*
AS68RDAHRA*
AS50PDAHRA*
B=Ø60mm
AS71PDAHRA*
AS50RDAHRA*
50P
C=165mm
AS71PEPHRA*
C=170mm
B=Ø60mm
70P
D=38mm
Wall hole
Ø60mm
Outdoor side
Thickness of wall
Piping hole pipe
G
Drawing of pipe
[ Left
Left-rear piping]
●
●In case of left side piping, cut away, with a nipper, the lid for left
piping.
●In case of left-rear piping, bend the pipes according to the piping
direction to the mark of hole for left-rear piping which is marked on
heat insulation materials.
1.Insert the drain hose into the dent of heat insulation materials of
indoor unit.
2.Insert the indoor/outdoor electric cable from backside of indoor
unit, and pull it out on the front side, then connect them.
3.Coat the flaring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely,
and make sure fixing with adhesive tape.
Lid for right
piping
Lid for left
Lid for under
piping
piping pipe
Fix with adhesive tape
●Indoor/outdoor electric cable and drain hose must be bound with
refrigerant piping by protecting tape.
[ Other direction piping ]
●Cut away, with a nipper, the lid for piping according to the piping
direction and then bend the pipe according to the position of wall
hole. When bending, be careful not to crash pipes.
●Connect beforehand the indoor/outdoor electric cable, and then
pull out the connected to the heat insulation of connecting part
specially.
Fixing the indoor unit body
●Hang surely the unit body onto the upper
notches of the mounting plate. Move the
body from side to side to verify its secure
fixing.
●In order to fix the body onto the
mounting plate, hold up the body aslant
from the underside and then put it down
perpendicularly
Unloading of indoor unit body
●When you unload the indoor unit, please use your hand to arise
the body to leave agraffe, then lift the bottom of the body outward
slightly and lift the unit aslant until it leaves the mounting plate.
agraffe mounting plate
4
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
●Remove terminal cover at right bottom corner of
indoor unit, then take off wiring cover by removing
its screws.
Indoor/outdoor
electric cable
Heat insulation
Piping
material
Pipe
supporting
Drain hose
plate
mounting plate