BASIC INSTALLATION INSTRUCTIONS
For mobile fuel tanks, the pump mounts to the tank bung by way of the pump inlet flange.
For Telescoping Steel Suction Pipe: Allow telescoping tube to extend fully to the bottom of the tank.
For Custom Suction Pipe: To avoid
penetrating the tank, we recommend
leaving a minimum of 1-2" of the
pipe off the bottom of tank. We further
recommend cutting the suction pipe to a
30-45 degree angle for improved flow.
The mobile tank must be equipped
with a vent cap. (Diagram 1)
INSTRUCTIONS BEFORE PROCEEDING WITH DC WIRING
The pump needs to be electrically bonded to a vehicle frame for mobile tanks or a grounding rod for stationary
tanks. To electrically ground pump for mobile application insert green screw through eyelet of furnished green
bonding wire assembly and fasten it securely to the junction box (Diagram 2). The other end of the wire is to be
stripped of insulation and the bare wire securely bonded to the vehicle or on/off road trailer frame for mobile
tanks (Diagram 3).
INSTALLATION, MECHANICAL PROCEDURE
Step 1: Install suction pipe onto inlet bung adapter.
Telescoping Section: 14" - 23-11/16" Inches. (For use in tanks 14" - 27" deep. For tanks greater than 27" deep, use
provided extension. For tanks greater than 36.5" deep, use custom pipe).
Extension Section: 13- 3/4" Inches. If extension section is used then thread sealant
must be used on both ends of the pipe.
A. Retrieve inlet bung adapter and 3-piece suction pipe (2-piece telescoping and1-piece extension).
B. When the extension piece is used with the telescoping section, the length is 27-3/4" - 36-7/8".
C. Measure tank size then use the appropriate length.
D. Attach the suction pipe to the inlet bung adapter. Thread suction pipe into the inlet bung 1.5
to 2.5 turns past hand tight with a pipe wrench.
Threaded pipe joints and connections must be sealed with the appropriate sealant
or sealant tape to prevent leaks.
Diagram 2
Threaded pipe joints and connections must be sealed with the appropriate
sealant to prevent leaks for fuel transfer.
Diagram 1
Bonding
Screw
Vent Cap
1-2"
Min.
Diagram 3
Attach Ground Wire to Vehicle