Installation and User Manual Himalaya Elite
2.12. Locating the connecting box for the connection cable in the sauna room
A = Specified minimum safety clearance
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box must be
clear of obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and regulations of the
local energy supplier.
Figure 3 Location for the connection box
2.13. Remote controlling
The Heater can be remotely controlled by connecting a closed contactor, which can be pulse triggered, to connectors 3
and 4 of a RJ10 circuit board. The recommended cable size is AWG 24 or 26. The maximum length of an AWG 24 cable is
200 m.
The maximum length of an AWG 26 cable is 130 m.
Note! The sauna standard requires a door switch if the sauna heater is controlled from outside the sauna.
An indicator light can be connected to the remote button terminal, it will be lit up when the remote command is activated.
The indicator light shows an error by blinking rapidly, this error is caused by keeping the sauna door open for more than
5 minutes, the sauna heater will be shut down automatically.
The remotely operated sauna heater stays on as long as the setting in the control panel (in private us max 6h). The
sauna heater can be shut off at any time by the remote-control device.
2.14. Order of RJ 10 connectors
NOTE: Incorrect connections may break a circuit board.
Additional sensor (NTC)
Pin 1
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
Sensor (Sec/NTC)
Pin 1
End stop
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
End stop
Table 3 RJ 10 connectors to circuit board
A
helo
Remote control switch (Ext switch)
Pin 1
3.3 V
Pin 2
CPU
Pin 3
To switch
Pin 4
To switch
GND
3.3 V
CPU
10V
A
3.
1.
2.
Pin 1
Pin 2
GND
Pin 3
12 VDC
Pin 4
Figure 4 DIP switch positions
for using a heater
Door switch
Alarm LED
GND
Door
GND
switch
Door
12 VDC
switch
9