Descargar Imprimir esta página

Campbell Hausfeld HS5380 Manual De Instrucciones página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS (CONTINUED)
Direction of Rotation
NOTE: Improper rotation will result in reduced
compressor life.
The direction of rotation must be counterclockwise
(as shown by the arrow on the flywheel in Figure
6) while facing the flywheel side of the pump. The
motor nameplate will show wiring information for
counterclockwise rotation.
The proper direction is very important. The direction
of rotation of 3 phase motors can be reversed by
interchanging any two motor-line leads. For single phase
motors, refer to the motor nameplate.
Lubrication
This unit contains no oil. Before
operating compressor, fill to the center
of the sight gauge (see Figure 7).
Using any other type of oil may shorten
pump life and damage valves.
RECOMMENDED OIL (2 OPTIONS)
Single viscosity SAE 30 ISO100 nondetergent
compressor oil. Part number ST125303AV (0.5 qt) or
ST126701AV (4 qt).
10W30 synthetic oil such as Mobil 1
OIL CAPACITY
Approximately 0.5 quarts
Fill the pump with oil to the center of the sight gauge
using oil fill opening (see Figure 7). Do NOT fill the pump
through the breather cap opening as this may cause oil
to leak and spray out during operation.
NOTE: Some residual oil may still be in the pump from
factory testing leaving a thin coat on the sight gauge;
however, there is not enough oil to operate the unit.
10
Figure 6- Direction of rotation
®
or CE0032 (1 qt).
Figure 7
Full
Low
Sight Gauge
Oil Drain Plug
Oil Fill
Breather Cap

Publicidad

loading

Este manual también es adecuado para:

Ce3000Hs5180Ce3001