Installation instructions
Installing your dual fuel range
IMPORTANT:
Please read the following instructions, as well as the Important Safety Instructions
section at the front of this manual, completely and carefully BEFORE installing
and/or operating the gas range. Improper installation, adjustment, service, or
maintenance can cause personal injury or property damage.
Step 1. Unpack the range
Remove all packaging materials. Failure to remove packaging materials could
result in damage to the appliance.
Inventory all loose parts against the Parts supplied components listed on page 9.
Check for shipping damage and/or missing parts. Any damage and/or missing
parts should be reported to your local retailer.
Step 2. Meeting electrical connection requirements
CAUTION
For personal safety, do not use an extension cord with this appliance. Remove
house fuse or open circuit breaker before beginning installation.
16 English
Install_NY63T8751S_DG68-01242A-00_EN+MES+CFR.indb 16
NOTE
To order parts or accessories, contact your
local retailer or refer to the last page.
NOTE
To ensure proper installation, we strongly
recommend that you hire a professional
installer.
This appliance must be supplied with
the proper voltage and frequency, and
connected to an individual properly
grounded branch circuit, protected by a
circuit breaker or fuse having amperage
as specified on the rating plate. The rating
plate is located on the bottom side of the
control panel.
We recommend you have the electrical
wiring and hookup of your range connected
by a qualified electrician. After installation,
have the electrician show you where your
main range disconnect is located.
Check with your local utilities for electrical
codes which apply in your area. Failure
to wire your oven according to governing
codes could result in a hazardous condition.
If there are no local codes, your range
must be wired and fused to meet the
requirements of the National Electrical Code,
ANSI/NFPA No. 70–Latest Edition. You can
get a copy by writing:
Effective January 1, 1996, the National Electrical Code requires that new
construction (not existing) utilize a 4-conductor connection to an electric range.
When installing an electric range in new construction, follow Steps 2 and 3 for
4-wire connection.
You must use a 3-wire or 4-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt,
60 hertz electrical system.
If the electrical service provided does not meet the above specifications, have a
licensed electrician install an approved outlet.
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
2020-03-27
11:10:06