2. Remove the V-belt cover.
3. Examine the V-belt for damages and wear. Replace
the V-belt if it is necessary.
4. Do a check of the V-belt tension.
5. If the V-belt tension is not sufficient, do this
procedure:
a) Loosen the screw on the belt tensioner (A).
b) Push the belt tensioner rearward.
c) Tighten the screw on the belt tensioner.
6. Install the V-belt cover.
2425 - 001 - 12.04.2024
Note:
cover that can be used to do a check of the tension.
To examine the V-belt for damages it is necessary to
remove the V-belt cover.
To replace the oil in the eccentric
element
1. Remove the oil drain plug for the eccentric element
and connect a hose.
A
There is an inspection hole on the V-belt
15