13. INSTALL THE HOOD
Hold the hood until it is completely secured to the wood
mounting strip.
I
(
)
NTERNAL BLOWER
S
ONLY
Run power cable to installation location. Remove the electrical compartment
cover. Insert the cable in the hood and tighten the wire clamp to secure the cable.
A
LL INSTALLATIONS
Rest the back cavity of the hood on the wood mounting strip.
Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4" (for 30" and 36" width hoods) or (6) screws (for 42" and 48" width
hoods) provided at locations shown. Drill (3) 3/16" size holes into the drywall for wall anchors through the existing holes in the inside hood
back in the locations shown. Then, install the three wall anchors with the remaining no. 8 x 3/4" screws and the (3) washers provided.
For a non-ducted installation, go to step 15, Connect the wiring.
14. ROUGH-IN PLATE LOCATION
Run power cable to installation location. For ducting through top of hood, existing
plate remains in place on inside back of hood.
For ducting through back of hood, remove existing plate from inside back of hood
and remove the rough-in plate from the top of hood. Attach the plate to inside top
of hood to cover hole. Secure to threaded studs with same (4) nuts. Install the
rough-in plate to the back of hood so that the wiring box is located on the right
side as you are facing the hood.
Connect ducting to rough-in plate as you are installing the rough-in plate. Use
metal foil duct tape to make all joints secure and air-tight.
15. CONNECT THE WIRING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
Remove wiring cover from rough-in plate or electrical compartment and set aside.
INTERNAL BLOWERS:
The ORANGE wire (A) is for make-up air device connection only.
If there is no make-up air device, never remove the cap on the
ORANGE wire end.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
CAUTION
(EXTERNAL BLOWERS HOODS ONLY)
(ALL BLOWERS)
Connect cable into wiring box using wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and GREEN
or bare wire under GREEN ground screw.
CAUTION
Reinstall wiring cover.
HD0262
WARNING
!
11
M
OUNTING SCREWS LOCATION
HD0264
W
ALL ANCHORS LOCATION
R
-
OUGH
IN PLATE
ON TOP OF HOOD
L
OCKNUTS
L
OCKNUTS
P
LATE ON BACK OF HOOD
HE0088
W
I R I N G
COVER
A