DIAGNOSIS DE AVERÍAS
TROUBLESHOOTING
Symptom
No water is reaching the cooler.
The unit only runs in FAN mode and
the control panel shows warning
(humidity and temperature
sensor error).
The unit only runs in FAN mode and
the control panel shows warning
(water pump error).
The unit only runs in FAN mode and
the control panel shows warning
(water supply error).
The unit only runs in FAN mode and
the control panel shows warning
(excessive slant).
Water overflows and exits through
the interior console windows or
towards outside the cooler.
Water overflows and exits through
the interior console windows or
towards outside the cooler, and the
control panel shows warning
(excessive slant).
Cause
The vehicle's water pressure system operates via
electric taps, meaning pressure is only present when
the tap is opened.
• Humidity and temperature sensor error.
• Water pump failure.
• Water supply error.
• The inclination of the evaporative cooler is, in any
direction, greater than 9º.
• The level probes are not working properly.
• The electrovalve does not close.
• The inclination of the evaporative cooler is, in any
direction, greater than 9º.