After a full charge, if the battery is not disconnected from the charger, it remains in trickle charge
mode. The default mode is OFF output.
mode 1 [6v] (6.8v/1.0a) and (7.2v/0.6a)
This mode is suitable for charging 6V batteries with capacity range from 1.2-12Ah in normal
conditions. Connect the output terminals of the charger to the battery with right polarity. Connect
the power cord to the power outlet to begin charging.
Press the selection button
the corresponding LED display
electronic system will automatically start the charging with a current of 5.25V~6.8V/1.0A±10%
and 6.8V~7.2V/0.6A±10%. Charging shall continue in several stages:
9
capacitance verification stage (charger on 30 minutes off 30 minutes) when battery voltage
≥6.8-0.15V/0.2A at this stage all intermediate charging status LEDs display
9
will turn on one by one until, finally LED display
current (0.1A±10%) is now available to battery for maintenance.
mode 2 [12v] (13.6v/1.0a) and (14.4v/0.6a)
This mode is suitable for charging 12V batteries with capacity range from 7.2-60Ah in normal
conditions. Connect the output terminals of the charger to the battery with right polarity. Connect
the power cord to the power outlet to begin charging.
Press the selection button
the corresponding LED display
electronic system will automatically start the charging with a current of 10.5V~13.6V/1.0A±10%
and 13.6V~14.4V/0.6A±10%. Charging shall continue in several stages:
9
capacitance verification stage (charger on 30 minutes off 30 minutes) when battery voltage
≥13.6-0.3V/0.2A at this stage all intermediate charging status LEDs display
will turn on one by one until, finally LED display
9
current (0.1A±10%) is now available to battery for maintenance.
rescuing drained Battery
When charger is connected to a battery, before the start of charging process, the charger
automatically detects the voltage of the battery. If voltage is below 1V (for 6V battery) and 7.5V
(for 12V battery) the Carpoint charger will not start due to its internal safety circuit. It initiates
recovery charging mode by applying a high voltage 8V (for 6V batteries) or 16V (for 12V
batteries) at 200mA±50mA if the voltage is > 1.0V (for 6V batteries) or > 8V (for 12V batteries).
8
11
to select Mode 1
will light up. If no further process is activated, the
5
10
until battery is fully charged up to 7.2V±0.125V. During battery
11
to select Mode 2
will light up. If no further process is activated, the
6
until battery is fully charged up to 14.4V±0.25V. During battery
10
5
. After executing this operation
7
10
will turn on. The Trickle
6
. After executing this operation
7
will turn on. The Trickle
10
8
7
8
,
,
8
7
,
8
,