Ensure that no part of the refrigerant circuit is damaged when
transporting and installing the appliance.
Where possible, always transport the appliance upright. If
tilted to an angle of more than 40° during transport, wait
4 hours before connecting it to the mains and switching it
on to enable the refrigerant circuit to return to normal after
transport.
Do not place the appliance on its side or back, as this can
cause oil from the compressor to enter and block the
refrigerant circuit.
Do not expose the appliance to rain or spray water.
.. Installation and electrical connection
...
Location
NOTICE!
Possible material damage!
Risk of damage to the appliance due to improper
handling
Install the refrigerating appliance in a dry and ventilated
room. The room should be approx. 4 m² to ensure that
sufficient air volume is available if the refrigeration system
becomes damaged.
Take the space requirements into consideration when setting up
the appliance (see '7.1. Setting up the appliance' on page 106).
The appliance is suitable for climate class N (see the type plate).
The cooling performance of the appliance is guaranteed at
ambient temperatures from 16°C to 32°C. If temperatures deviate
from this range, the appliance performance may be reduced.
Do not use the appliance outdoors.
Do not expose the device to extreme conditions. Avoid:
high humidity or wet conditions
extremely high or low temperatures
direct sunlight
open flames.