assembly, do not install the equipment and replace it even if there are no patent damages to the plastic
parts. If the system is subject to water hammering, install an appropriate damping system. If the water
pressure can exceed the maximum operating pressure of the filter even for short periods, install a
protective pressure reducer.
Avoid overhead installation in order to prevent damages to property or persons in the event of
a fall, a collapse or water leakages.
B1.5 Electrical checks after installation
After connecting the filter to the power supply, the display will automatically turn on; the filter reaches the
filtration stage and the display switches off.
After this stage, check the operation of the circuit by manually pressing the buttons
simultaneously, until the motor starts; the filter performs a backwashing procedure. Check the correct
functioning of the backwash solenoid valve, if installed (optional). The solenoid valve is in closed position
during the backwashing operations performed by the filter and in open position during filter operation.
B1.6 Hydraulic checks after installation
After having opened the water upstream of the equipment, check for any leaks;
5)
Check that the appliance is correctly positioned so as to ease ordinary maintenance operations.
-
6)
Check that the system is equipped with: disconnector, by-pass, sampling taps
7)
Verify that there are no leaks from the inlet and outlet fittings and from the filter drain.
8)
Check the compliance of the system with any local regulations or recommendations issued by the
competent local offices
If in doubt, contact Acqua Brevetti SRL (tel. +39.049.8973432, e-mail: info@acquabrevetti.it).
B1.7 Allowed assembly diagrams
The filter is supplied with the water inlet on the right (see installation 1 on the next page).
The plate can be rotated by 180° and, therefore, it allows inverting the position of the input and output
connections.
BravoMATIC - ENGLISH
MAN139 PAGE E-17