1.9
RS485 connection
NOTE
A network cable of category 5E or higher is required for connection to the RJ45 socket.
For outdoor use, UV resistance and a maximum installation length (over all inverters) of 1000 m are
permitted.
Damage to the inverter due to electrostatic discharge
Internal components of the inverter can be irreparably damaged by incorrect wiring between
the power and signal cables. All warranty claims are thereby rendered invalid.
› Ensure that the cable is correctly assigned.
The device has been installed on the mount.
1 Unscrew the cover cap of the communication connection (COM1 or COM2) (see illustration below, observe the sequence
and directions of the arrows). Feed the network cable through the thread sleeve (incl. forcing nut).
2 Feed the network cable through the thread sleeve (incl. forcing nut).
3 Configure the communication line as shown in Figure 21 (according to DIN 46228-4, provided by the customer).
4 Plug the network cable into COM1 or COM2 (see Fig. 19. Note the sequence and directions of the arrows)
» The RS485 Cable is connected to the device.
5 Tighten the thread sleeve, then tighten the forcing nut at the end (pos. 5 and 6).
Fig. 20: Insert the network cab
Fig. 22: Connect the network cable
2
Commissioning
Note: The device is put into operation via an APP using a mobile end device. The APP called KACO Tool is available for
Android or iOS (See QR code for Google Playstore or App Store in the appendix of this quick guide).
A detailed description of WiFi network configuration, parameter settings and firmware updates can be found in the
download area of the
KACO new energy
Note: No password is required for the initial start-up. However, a device-specific password is required for subsequent
parameter changes. The serial number on the type plate of the device is required for this. To assist you as quickly as
possible, please make a note of this number before contacting our customer service.
KACO blueplanet 25.0 NX3 M2 KACO blueplanet 30.0 NX3 M2 KACO blueplanet 33.0 NX3 M2
Legend
1
2
3
4
homepage under application note: Settings for WI-Fi APP.
Fig. 21: Cable pin assignment
Cover cap
Network cable
Thread sleeve
Sealing with forcing nut
Page 11