C3.
ADAPTING BLOWER
FOR RECIRCULATION
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
Remove and save screws that hold blower plate to
1
the oven.
Slide the blower plate from under its retaining
2
flange and lift it off. Remove and save screw that
holds the blower motor to oven.
Retaining
Flange
Installation Instructions
Blower Plate Screws
Back of
Oven
Blower Plate
Blower Motor
Screw
Carefully pull out the blower unit. The wires
3
will extend far enough to allow you to adjust the
blower unit.
Roll the blower unit 90° so that fan blade openings
4
are facing toward the front of the oven.
BEFORE: Fan Blade
Openings Facing Up
AFTER: Fan Blade
Openings Facing
Forward
NOTE: Make sure wires remain routed in the grooves
of the motor frame.