Following Lines With Higher Location Depth - Amprobe AT-2032 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Following lines with higher location depth.

Example 10 (dual-pole application)
Conditions:
1. The current circuit must not be live.
2. Connect the transmitter in compliance with the figure.
3. The distance between go-and-return line must be minimum 2.0m to 2.5m or more.
4. The receiver must be held at a right angle to the cable.
5. Proceed as described in the application example.
If the dual-pole application is carried out on multi-wire cables (e.g. NYM 3x1.5mm2), the
location depth is widely limited. The reason herefore is that the go-and-return lines are
installed very closely. Thus, a strong distortion of the generated magnetic field occurs. The
electro-magnetic field may not develop at the bottleneck.
This limitation can easily be eliminated when using a separate conductor to simulate the
return line. This separate conductor allows a larger spreading of the electro-magnetic field.
Any conductor or cable reel can be used as separate return conductor. When tracing the
conductors, special care has to be taken that the distance between go-and-return-line is larger
than the location depth. In practical applications, this amounts to approx. 2.0 m. Furthermore,
the receiver has to be held at a right angle to be cable to be traced. For this application,
humid walls, plaster, etc. have only an insignificant influence on the location depth
25

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido