BFT LEO B CBB 3 230 L02 Instrucciones De Instalación página 39

Ocultar thumbs Ver también para LEO B CBB 3 230 L02:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
Logic
Definition
Configuration of
AUX 0 output.
AUX 0
20-21
AUX 3
Configuration of
(Setup for
AUX 3 output.
LEO B CBB 3 120
26-37
F02)
Fixed code
FIXED CODE
Setting the
Protection
protection level
level
Serial mode
(Identifies how
SERIAL MODE
board is configured
in a BFT network
connection).
Address
ADDRESS
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
6
4
Output configured as Stair Light
5
Output configured as Alarm
6
Output configured as Flashing light
7
Output configured as Latch
 
8
Output configured as Magnetic lock
9
Output configured as Maintenance
10
Output configured as Flashing Light and Maintenance.
11
Not used
0
12
Output configured as Antitampering
13
Output configured as Gate Status
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
 
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in
standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by repea-
0
ting the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the receiver's
memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
0
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interference,
if any.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
0
 
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network with no smart
2
module (fig.F)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network with no smart
3
module (fig.F)
Identifies board address from 0 to 119 in a local BFT network connection.
0
 
[ ___ ]
(see U-LINK OPTIONAL MODULES section)
Optional extras
LEO B CBB 3 230 L02 - LEO B CBB 3 120 F02
39
-