3 Symbols on the Product
Communication disturbances in the local network
The IP address range 192.168.12.0 to 192.168.12.255 is occupied for communication
amongst SMA products and for direct access to SMA products.
Communication problems might occur if this IP address range is used in the local network.
• Do not use the IP address range 192.168.12.0 to 192.168.12.255 in the local network.
Electrical installations (for North America)
All installations must conform with the laws, regulations, codes and standards applicable in the
jurisdiction of installation (e.g. National Electrical Code
• Before connecting the product to the utility grid, contact your local grid operator. The
electrical connection of the product must be carried out by qualified persons only.
• Ensure that the cables or conductors used for electrical connection are not damaged.
3
Symbols on the Product
Symbol
Explanation
Beware of a danger zone
This symbol indicates that the product must be additionally grounded if addi-
tional grounding or equipotential bonding is required at the installation site.
Beware of electrical voltage
The product operates at high voltages.
Beware of hot surface
The product can get hot during operation.
Danger to life due to high voltages in the inverter; observe a waiting time of 5
5 min
minutes.
High voltages that can cause lethal electric shocks are present in the live com-
ponents of the inverter.
Prior to performing any work on the inverter, disconnect it from all voltage
sources as described in this document.
Observe the documentations
Observe all documentations supplied with the product.
Operation LED
Indicates whether the product is in operation.
Error
Together with the red LED, this symbol indicates an error. Observe the docu-
mentation.
12
SBSExx-US-50-ISS-xx-10
SMA Solar Technology AG
®
ANSI/NFPA 70.
Quick Reference Guide