Descargar Imprimir esta página

ProKlima FN-110166.1 Manual Del Usuario página 42

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
PARTS DESCRIPTION
1.
Fan guard
2.
Fan blade
3.
Stand
4.
Handle
5.
Speed switch
6.
Control box
ASSEMBLY OF YOUR FLOOR FAN
Your Floor Fan has been boxed assembled for immediate use.
OPERATING INSTRUCTIONS
1.
Plug the power cord into a suitable socket.
2.
Press the switch on the top of control box to select a speed, 0 = OFF, 1 = Low Speed, 2 = Medium Speed, 3 =
High Speed.
3.
Tilting Angles: By pushing the fan-guard, you can adjust the fan to the preferred elevation.
CAUTION: Press only one of the speed control button at a time. Permanent damage to the switch housing may
result if two or more of the buttons are pressed simultaneously.
CLEANING
Before servicing the fan and after each occasion of use, switch off the appliance and unplug the mains
cable from the socket.
Never immerse the appliance in water (danger of short-circuit). To clean the appliance, only wipe it down
with a damp cloth and then dry it carefully. Always take out the mains plug first.
Take care that excessive dust does not build up in the air-intake and air-outlet grille, and clean it
occasionally using a dry brush or vacuum cleaner.
TECHNICAL DATA
Operating voltage:
220-240V ~ 50Hz
Power consumption: 100W
Eco design requirements
Product information requirements
Maximum fan flow rate (F)
Fan power input (P)
Service value (SV)
Measurement standard for service value
- 41 -
102.16 m³ /min
110.13 W
0.93 (m³ /min)/W
IEC 60879: 1986 (corr.1992)
FN-110166.1 / FN-110166.2

Publicidad

loading

Este manual también es adecuado para:

Fn-110166.2