Note: It is recommended to connect the inverter's DC input terminal directly to the battery terminal.
Avoid connecting it to the charge source terminal. Otherwise, the charging voltage spikes from the
charge source may trigger over-voltage protection in the inverter.
Wire size and circuit breaker
Wires, terminals, and circuit breakers for the battery:
Model
MI-500
MI-1000
MI-1500
MI-2000
MI-3000
1. According to the recommended battery wire size, it is necessary to use 2 battery wires connected
in parallel for MI-1500 and MI-2000.
2. MI-3000 requires 4 battery wires connected in parallel.
3. Note: The above wire size and circuit breaker size are for reference only; please choose a suitable
wire and circuit breaker according to the actual situation. If there is a considerable distance
between the inverter and the battery, use larger wires to minimize voltage drop and enhance
system performance.
Battery wire size
terminal
10mm²/7AWG
RNB8-6S
25mm2/3AWG
RNB38-6
25mm2/3AWG
RNB60-6
35mm2/2AWG
RNB70-10
25mm2/3AWG
RNB80-10
Ring
Circuit breaker
DC/2P—63A
DC/2P—125A
DC-100A(2P in
parallel)
DC-125A(2P in
parallel)
DC-125A(3P in
parallel)