Initial Use
compressed air supply
For trouble-free operation of the device, a sufficient
supply of filtered, dry, oiled compressed air is
required.
— If compressed air is generated using compressors,
the air humidity naturally present condenses out
and collects as condensation in the pressure tank
and pipe lines.
— This condensation must be removed by a water
separator.
Check and drain the water separator daily, oth-
erwise corrosion can occur in the compressed air
system and increase wear.
Outlets that are provided for the devices should
be equipped with a compressed air service
unit (filter/water separator/oiler) directly at the
coupling point. Check oilers daily and fill with the
recommended oil.
The air volume is as important as the air pressure.
Dirt in the hose connectors or water in the system
can impair the air flow so that an insufficient volume
of air is available although the indicated pressure is
sufficiently high.
Before the device is examined for a fault, the air
supply and the compressed air source must first
be checked for possible causes that could impede
the volume flow (dirt, water).
connecting the device to a com-
pressed air supply
attention!
The device drive must always be adequately
lubricated.
Oil the device before first use, then oil daily.
¾
If the tool has not been used for several days,
¾
manually add about 5 drops of pneumatic oil to
the compressed air connection.
attention!
Operate only with clean, dry compressed air at
a regulated pressure of 6.2 bar (measured at the
air inlet).
DanGer!
Risk of injury due to the failure of quick-
release couplings and consequently
uncontrolled flailing hoses.
Do not use quick release couplings
¾
directly at the device nor closer
than 20 cm to the device.
Screw the hose connector [7] to air inlet [5] of
the device.
Push a suitable hose clamp [8] on to the com-
pressed air hose [9].
Push the compressed air hose [9] up to the stop
on the hose connector [7].
Tighten the hose clamp [8] just before the end of
the compressed air hose [9].
Operation
Push a suitable tool/bit (Würth system accessory)
on to the tool holder [1].
Check that the tool bit is correctly seated.
Set the direction of rotation [3] and torque [2] at
the switch.
Symbol
Meaning
Clockwise rotation
Anticlockwise rotation
1
Torque level 1
2
Torque level 2
3
Torque level 3
4
Torque level 4
Grip the device by the handle [4].
Switching on: Press switch [6].
Switching off: Release switch [6].
Maintenance / Care
caUtIon!
Risk of injury or material damage.
Clean and service the device only
¾
when it is disconnected from the
compressed air supply.
Keep the casing and handle dry, clean and free
from oil. Never use brake fluid, petrol or solvent
for cleaning.
Check screws for tight fitting.