Descargar Imprimir esta página

TESY CN03 YYZ MIS F Instrucciones Para El Uso Y Mantenimiento página 4

Convector eléctrico portable
Ocultar thumbs Ver también para CN03 YYZ MIS F:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
foot. (fig. 2b)
EN
The joint is secure in case the portable electric convector heater stands
horizontally on the floor after its feet installation has been completed. Do not
use the power cord as a pulling rope in order to move the portable electric
convector heater; any movement of the portable electric convector heater
should be done when it is cold.
Position the portable electric convector heater with installed feet on the floor
and before connecting it to the power socket check if all instructions from
the very beginning of this manual have been followed correctly (Important
instructions and safety measures). The correct position is – the control electric
should be at the top of the appliance and the feet – on the floor!
BATHROOM OPERATION
The portable electric convector heater must be installed in accordance with
the normal trade practices and in compliance with the national legislation (EU
electricity directives and regulations concerning special installations and places
of operation including bathrooms, shower cabins HD60364-7-701(IEC 60364-7-
701)). (fig. 3)
In case this portable electric convector heater is to be used in a bathroom or
other similar room, the following installation requirements must be observed:
the portable electric convector heater is with IP24 protection (water drops
protection). Hence it can be installed in "Volume 2" (see the diagram below) in
order to avoid the risk of the control board (power switch and thermo regulator)
being reached by a person who is in a shower or a bathtub. The minimum
distance between the appliance and a water source should be not less than
1 meter! If you do not feel sure about the installation of this portable electric
convector heater in a bathroom, we recommend you to consult a professional
electrician.
Note: If the above-mentioned instructions cannot be implemented, it is
recommended to install the appliance in "VOLUME 3".
In wet premises the power source must be installed at a height of at least 25 cm
above the floor (bathrooms and kitchens).
The installation must be equipped with a safety fuse, and the distance between
the fuse contacts in disconnected condition should be at least 3 mm.
Thank you for choosing CN03 portable electric convector heater. This is a product
providing heating in winter depending on the consumers' needs for comfortable
room temperature. If operated and taken care of properly in accordance with these
instructions, the appliance will provide you with many years of useful operation.
OPERATION INSTRUCTIONS
MECHANICAL CONTROL
Operation modes - (fig. 4)
Turn the portable electric convector heater on by pushing the switch in
position "I" (turned-on), then turn the regulator to the desired level (1 to 6)
as you take into account the following relation between the power levels:
* – anti-freezing mode/ enabled when room temperature falls below 5°C
1 / 2 – economy mode/ it maintains low room temperature/ this mode is
recommended to be used at night and when there are no people present in
the room. This mode permits to maintain the set room temperature while
saving energy.
3 / 4 / 5 – comfort mode/ it maintains moderate room temperature/ this
mode is recommended to be used to maintain relatively high comfortable
room temperature during the day.
6 – maximum power mode / it maintains HIGH room temperature/ this mode is
recommended to be used when you need maximum high room temperature
Important: Thermo Regulator digits do not correspond to certain room
temperature levels, but they can be used by users to memorize the relation
TROUBLESHOOTING
Prior to contacting the Customer Service Center, please check the items in the table below.
PROBLEM
The appliance doesn't
work
Room does not get warm
enough although the
appliance is hot
Dirty marks appear on the
wall around the device
Sounds/Noises
Yellowish stains on the
grid
4
Operation and Storage Manual of Panel Heater
CAUSE
No power supply from the grid.Be sure that the product is
plugged in and that the electrical outlet is working.
Appliance overheating. High limit safety cut-out limits
heating output.
The heat demand of the room is higher than the appliance output.
Check if the power of your device is adapted to the size of
your room.
The dirty marks come as a result of air contamination.
Emitting faint noises during the heating process and shortly
after the set temperature is reached, is not something
unusual.
Such stains could be in result of covering the product with wet
clothes.
between room temperature and the thermo regulator settings.
When the room temperature is lower than the temperature that you have
set by the thermo regulator, the portable electric convector heater starts
its operation and will operate until the room temperature reaches the set
temperature level of the unit. When the room temperature is higher than
the adjusted temperature of the appliance, the portable electric convector
heater will automatically go into "Stand by" mode.
PROTECTION
The appliance is equipped with a safety thermo turn-off device, which
automatically turns the portable electric convector heater off in cases
of extreme temperature of the portable electric convector heater /i.e.
overheating of the appliance/.
The safety thermo turn-off device will automatically restore the
portable electric convector heater operation when the temperature of
the appliance falls below the permissible ultimate values.
TIP-OVER PROTECTION
This portable electric convector heater is protected with a safety switch that
turns off the appliance automatically when the portable electric convector
heater falls over, or is at an excessive angle from the horizontal. This helps
prevent accidents, and the portable electric convector heater will back to
last set mode when it is put back upright.
CLEANING
It is compulsory first to turn off the appliance through its power switch and
to disconnect it from the power socket. Before starting the cleaning session
you should wait until the portable electric convector heater cools down in a
disconnected state.
Clean the portable electric convector heater body with damp cloth, vacuum
cleaner or a brush.
Never immerse the appliance into water – there is danger for your life from
electric shock!
Never use gasoline, thinner or hard abrasive products to clean the appliance,
because they will damage the appliance coating.
STORAGE
Before putting the portable electric convector heater away let it cool down after
you have disconnected it from the power socket
Use the appliance original packing to store it, if the portable electric convector
heater will not be in use for a long period of time. By storing the product in its
original packing you protect it from excessive dirt and dust accumulation.
Never put a hot portable electric convector heater in its packing!
It is necessary the product to be stored at a dry and dark place, protected from
direct sun light.
It is explicitly forbidden to store the portable electric convector heater in damp
and wet premises.
MAINTENANCE OPERATIONS OF THE APPLIANCE
In case of appliance malfunction, please contact the authorized
service center closest to your location. /service centers are indicated in
appliance warranty documents/.
Important: In case of a claim and/or violation of your consumer rights,
please contact the supplier of this appliance at the indicated locations
or via the Internet page of the company: www.tesy.com
Environment protection instructions
Obsolete electric appliances contain valuable materials and consequently they
should not be treated as domestic waste! We ask for your cooperation and your
active contribution to protect the resources and the environment. Please submit
your out-of-use appliances to the organized buy-back stations (if there are such).
Plug into the power outlet and check position of the ON/OFF switch.
Eliminate the cause (cover, dirt or obstructions at the air inlet or outlet).
Observe minimum clearances according to mounting instructions.
Remove heat losses (Close windows and doors. Avoid constant venting.)
Recommended an average of 100 W/m2 for a ceiling height of 2,50m or
30W/m3
Make sure that some fresh air enters the room regularly, especially if it is used
for smoking.
Such effect is in result of the natural materials expansions during the
rapid temperature increase and following cooling of the metals used
for the product manufacturing.
Do not cover the product! Such actions are not allowed, because they block
the air convection and will damage the product irreparably, leading to serious
risk for your health and properties.
SOLUTION

Publicidad

loading