2. Wet vacuuming
WARNING
Never operate the machine without inserting filter or
special wet filter. The machine may be destroyed and
water may also escape.
○ Before carrying out any wet vacuuming, remove the dry
vacuumed material. This process will prevent severe
soiling and encrustation.
○ The appliance has a float system that enables it to
switch off the air flow when the maximum liquid level is
reached. When this happens, you will hear a distinct
change in the sound of the motor. Then switch off the
appliance and pull the plug from the socket. Only
vacuum liquids when the float is functioning properly
(see maintenance).
○ After switching off, some water may run back out of the
hose.
○ Before emptying, first of all take the suction hose out of
the liquid.
○ If you are then going to dry vacuum, insert a dry filter. If
there is frequent switching between dry and wet
vacuuming, we recommend the use of a second
(replacement) filter. Allow the filter, container and
accessories to dry: otherwise dust may adhere to damp
components.
○ Before storage: leave humid filter and the inside of the
dust container to dry completely.
3. Transport
○ L class: Leave the hose on the machine to prevent dust
from accidentally being released. (Fig. 13)
○ M and H class: with the hose disconnected, close the
suction inlet with the plug. Insert the hose ends into
each other so that no dust can escape from the hose.
○ Secure the suction hose or mains connection lead to
the appliance using the accessory fixture and rubber.
○ The upper part must be securely sealed to the container
- check that the snap locks are closed.
WARNING
The handle is only permitted for manual transport - not
for attachment to cranes or similar!
CLEANING
WARNING
Be sure to turn off the vacuum switch and disconnect
the plug from the power receptacle.
CAUTION
This device contains dust that is harmful to health.
Discharge and maintenance operations (including
disposal of the dust collection containers) must only be
carried out by qualified specialists wearing appropriate
protective clothing and equipment.
Clean the container and accessories with water. Wipe the
upper part with a damp cloth.
1. Emptying the Container
WARNING
Only permitted for dusts with occupational exposure
limits > 1 mg/m
3
(1) Pull the mains plug. Ensure the plug cannot be
reconnected accidentally.
(2) Open the snap locks. Remove the upper part of the
device from the container.
(3) Tip out the container.
2. Disposing of the fleece filter bag
(1) Pull the mains plug. Ensure the plug cannot be
reconnected accidentally.
(2) Put on a dust mask.
(3) Open the snap locks. Remove the upper part of the
device from the container.
(4) Carefully pull back the fleece filter bag from the suction
opening. Close the cap of the filter bag opening.
(5) Dispose of the vacuumed material in accordance with
legal regulations.
3. Dispose of PE disposal bags and special filter
bags for H-class.
(1) Insert mains supply plug.
(2) Switch on the dust extractor and clean the filter: Press
the Button for filter cleaning 'PressClean' (see "1.
PressClean" of "The DEVICE") .
(3) Switch off the dust extractor: turn the switch to the
"OFF" position.
(4) Put on a dust mask.
(5) Open the snap locks. Remove the upper part of the
device from the container. Before setting down the
upper part, turn switch to the "ON" position so that any
falling dust is vacuumed.
(6) Carefully remove the bag from the container wall and
close with the supplied cable binders.
For the special filter bag for H-class, close the cap of
the filter bag opening and then close the bag.
(7) Dispose of the vacuumed material in accordance with
legal regulations.
MAINTENANCE AND INSPECTION
1. General instructions
WARNING
○ Before performing any maintenance, always switch off
the device and remove the mains plug. Ensure the plug
cannot be reconnected accidentally.
○ Clean the device (see "CLEANING").
For maintenance by the user, the dust extractor must be
taken apart, cleaned and maintained, to the extent
possible, without endangering maintenance staff or
other people.
Preventive Measures
Appropriate preventive measures include: cleaning the
device before disassembly; providing local filtered forced
ventilation where the dust extractor is disassembled;
cleaning of the maintenance area and providing suitable
personal protective clothing and equipment.
2. Reduction in suction power
If the suction power decreases, carry out the following
steps:
(1) Clean the filter: Press Button for filter cleaning
'PressClean' (see "1. PressClean" of "THE DEVICE")
(2) Empty the container or replace the fleece filter bag or
PE disposal bag.
(3) Replace the filter, or shake it out, brush it off or remove
it, rinse under running water, dry and reinsert (see
"Replacing the filter").
3. Replacing the filter
(1) Clean the filter again before replacement ("1.
PressClean" of "THE DEVICE")
(2) Unplug power cable; Ensure the plug cannot be
reconnected accidentally.
(3) Open the snap locks. Remove the upper part of the
device from the container.
Loosen closure (see imprint). Remove filter cover and filter.
(Fig. 14)
Seal the old filter immediately in a dust-tight plastic bag and
dispose of it in accordance with regulations.
4. Water sensor
CAUTION
Regularly clean the mobile float that is incorporated in
the filter cage and check it for signs of damage.
5. Technical inspection
At least once a year, the manufacturer or a suitably
qualified and trained person must carry out a dust test,
e.g. to check for damage to the filter, verify that the
device is air-tight and that the control unit is functioning
correctly.
12