upwards out of the angle brackets. Clean the Fresnel lens with a damp, lint-free cloth and the
glass lens with a special lens cloth. Now place the Fresnel lens in front of the glass lens and fold
the bracket back downward until the locking pin engages.
D
Important safety notice! For safety reasons, the filter frame must always be in the
respective bracket on the light, even if no filter sheet is inserted!
CARE, MAINTENANCE AND REPAIR
In order to ensure the long-term, proper functioning of the device, it must be regularly cleaned
and, if necessary, serviced. The maintenance requirement depends on the intensity of use and the
environment in which it is used.
We recommend a visual inspection before each operation. Furthermore, we recommend carrying
out all the applicable service measures specified below once every 500 operating hours or, in
the case of a lower intensity of use, at the latest after one year. Warranty claims may be limited
should defects result from inadequate service and maintenance.
CARE (carried out by user)
WARNING! Before carrying out any care or maintenance, the power supply – and, if
possible, all device connections – must be disconnected.
PLEASE NOTE! Improper care can lead to impairment of the device or even its
destruction.
1. Housing surfaces must be cleaned with a clean, damp cloth. Make sure that no moisture can
penetrate the device.
2. Air inlets and outlets must be regularly cleaned of dust and dirt. If compressed air is used, make
sure that damage to the device is prevented (e.g. fans must be blocked in this case, as they
could otherwise over-rev.).
3. Cables and connectors must be cleaned regularly and dust and dirt must be removed.
E
F
25