Operating instructions
Type
06395
06602
06603
50051.0004
50051.0011
6
Operation
The maximum permissible pressure drop in the inlet lines to the safety valves may not exceed the 3 %
pressure difference between the response pressure and superimposed back pressure on the safety
valve.
Vibrations are to be avoided.
Check the following points prior to start-up:
All mounting and installation work are completed.
Compare the material, pressure, temperature and installation position with the layout plan for the
pipework system.
Dirt and residues have been removed from the pipeline and safety valve in order to prevent leaks.
6.1
Liftability (manual actuation for testing)
Liftable safety valves are equipped with an appropriate device above the spring cap.
Liftable safety valves can be made to open at ≥85 % of the set pressure without aids.
Typical lifting cases are initial commissioning, after breaks in operation and functional testing; the pro-
cedure is as follows:
Material
Thread
1/2''
3/4''
CW614N
1''
11/4''
1/2''
3/4''
1.4571
1''
11/4''
1''
1.4301
11/4''
1''
11/4''
CC491K
11/2''
2''
CW614N
1/2''
1.4301
1/2''
CC491K
1''
1.4301
1/2''
CC491K
1/2''
1/4''
CW614N
3/8''
Step 1: Pull the lifting knob / pull-ring upwards until blow-off
Step 2: Release the lifting knob / pull-ring.
herose.com
max. tightening torque [Nm]
Male thread
G
NPT
R; Rc
43
70
80
120
180
160
220
340
300
550
570
560
70
70
130
200
200
280
370
380
500
920
930
940
350
380
470
880
910
890
70
100
90
110
18
50
of the operating medium is clearly audible.
Female thread
G
NPT
R; Rc
49
110
90
70
180
160
150
340
300
240
570
560
70
180
150
120
290
270
250
550
470
390
910
890
110
250
220
170
390
390
220
550
530
340
880
980
48
110
90
70
180
150
110
250
220
33
12
21