PROBLEM
The lights blink 5 times every 5
seconds. The seat heater is not working
(A804053S01 and A804054S01 only).
The lights blink 6 times every 5 seconds.
The water is not heating up.
The lights blink 7 times every 5 seconds.
The water temperature sensor error.
The lights blink 8 times every 5 seconds.
The air dryer is not heating up, air fan
issue or air temp sensor issue.
The nozzle do not function properly.
The washing function does not work or fails
to spray.
The device shuts off while it is in use in
wash mode.
The device shuts off while it is in use in dry
mode.
The nozzle does not move back.
The device moves when sitting down.
Water comes out through the nozzle door
and the function is not activated.
* Should the problem persist, please call the Technical Assistance.
POSSIBLE CAUSE
The current on seat heating circuit is too
high (>25W).
The current on seat heating circuit is too
low (<5W).
The seat temperature set to off.
Water temperature sensor is damage.
Water temperature set to off.
Water temperature sensor is damage.
The air temperature sensor is damage.
The air fan is damage.
The nozzle head is dirty.
The filter in the shut-off valve is clogged or
there is a general supply failure.
The water pressure is too low.
The nozzle position is not correct.
User not properly seated.
The washing time exceeded 5 minutes.
There are a power failure.
The pre-set drying time of 5 minutes has
expired.
The power supply has been cut.
The engine of the nozzle has lost its
position.
The rear bracket of the product are not
tight enough.
28
SOLUTION
*
*
Chek seat heater temperature adjusment
(see 3.5) or reset heated seat temperature.
*
Check water temperature adjustment (see
3.1.3) or reset heated water temperature.
*
*
*
Clean the nozzle head (see 4.1.2).
Verify there is water supply from the mains
and clean the water filter from the shut-off
valve (see 4.2) and reset the product.
Adjust the water pressure (see 3.1.3).
Adjust the nozzle position (see 3.2).
Adjust the nozzle position (see 3.2).
Repeat cleaning function.
Check power cord or unplug and plug the
cord. Reset the product (see 4.3).
Reactivate the drying function.
Restore the main power. The nozzle goes
back automaically.
Reset the product (see 4.3).
Tighten the rear bracket.
*