BASIC PROGRAMMING FROM A PC
1.
CONNECT WITH THE PC
• Panel programming is done exclusively by means of a PC connected to the same LAN,
through of a web browser (Chrome preferably), accessing the IP address of the panel.
• Default IP address is: 10.1.0.1.
• The PC must have an IP address of the same range as the IP address of the panel.
2.
OPEN YOUR WEB BROWSER
Open your web browser, go to http://10.1.0.1 and log in with your username and password.
Default value:
• Username: admin
• Password: 123456
It is necessary to carry out a previous planning of the installation, to define the parameters to
assign to each device.
3.
NETWORK
Go to Network menu and change default IPv4
Settings according to the configuration of your local
network:
NOTE:
In case you don't know the IP address of the panel:
Press and hold push button #1 (bottom) until a sound is
emitted. Immediately, press push button #1 shortly. The
panel will announce its current IP address.
4.
PUSH BUTTONS (default)
1 10.1.1.1 (Bottom)
2 10.1.1.2
3 10.1.1.3
4 10.1.1.4
5 10.1.1.5 (Top)
5.
OUTPUT (default)
Idle status: C-NC closed
DTMF unlock tone: #
6.
MEET INTEGRATION
This panel can be integrated with Meet devices (min fw: v 3.50) and Meet Me call divert
(licence Ref.1496 not included).
Duration of door opening: 4 seconds
Feedback tone: bell.wav