Descargar Imprimir esta página

LG LSIL6334 E Serie Manual Del Propietário página 19

Cocina inducción eléctrica
Ocultar thumbs Ver también para LSIL6334 E Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

en-us_main.book.book Page 19 Monday, October 30, 2023 10:14 AM
7
Tighten the 3 screws securely into the
terminal block.
• The center screw now attaches the bent up
ground strap to the block.
a
Black
b
White
c
Red
d
Terminal Block
e
Ground Strap
f
Ground Screw
g
Cord/Conduit Connection Plate
h
Bend strap up and attach.
3-Wire Connection: Conduit
WARNING
• If screws are not tightened securely, it can result
in electrical spark and severe personal injury or
death.
Conduit Installations
CAUTION
• Do not install the conduit without a strain relief.
1
Remove the cord/conduit connection plate
from the rear of the oven and rotate it.
• The conduit hole (1 1/8") must be used.
2
Prepare the conduit wires as shown below.
a
Cord/Conduit connection plate
3
Install the conduit strain relief.
1) Insert the strain relief in the 1 1/8 in. (2.8
cm) conduit hole.
2) Install the conduit through the body of
the strain relief and fasten the strain relief
with its ring.
NOTE
• For conduit installations, purchase a strain relief.
4
Reinstall the cord/conduit connection plate.
Conduit Connections
If the wire in the conduit is copper it must be 8 or
10 AWG wiring.
If the wire in the conduit is aluminum it must be 6
or 8 AWG wiring.
1
Loosen the lower 3 screws from the terminal
block.
2
Insert the bare wire (white/neutral) end
through the center terminal block opening.
Do not remove the ground strap connections.
3
Insert the two side bare wire ends into the
lower left and the lower right terminal block
openings.
INSTALLATION
19

Publicidad

loading