- Dehumidifying mode: The speed can be adjusted by pressing the fan speed button
(high speed or low speed). If the indoor humidity is higher than or equal to 3%, the com-
pressor starts to dehumidify. After reaching the humidity set, the humidity function will
stop and the compressor will stop. After the dehumidification conditions are met, the
dehumidification function will resume operation.
- Dryer mode: When this function is turned on, the dehumidification operation is perfor-
med. The wind speed is locked to high speed and it cannot be adjusted. Select that mode
to help you drying your clothes faster.
Setting the timer
Scheduled power-off function:
When the dehumidifier is running, press the timer button and then press timer up or ti-
mer down buttons to set the desired hours. The timer digital display will flash 5 times for
confirmation and the timer indicator light will be on. Timing range is from 1 to 24 hours
and it will increase 1 hour by each press. When time is up to your setting the unit will turn
off. To cancel the timer selection at any time, press the timer button twice.
Scheduled power-on function:
When the dehumidifier is on standby, press the timer button and then press timer up or
timer down buttons to set the desired hours. The timer digital display will flash 5 times
for confirmation and the timer indicator light will be on. Timing range is from 1 to 24
hours, it will increase 1 hour by each press. When time is up to your setting the unit will
turn on. To cancel the timer selection at any time, press the timer button twice.
Auto defrosting function
1- When the dehumidifier is in defrosting function, the compressor is turned off and the
fan gets defrosted by high winds.
2- When the room temperature is less than or equal to 16°C, the temperature of the coil
is not detected. According to the ambient temperature, it is as follows:
- Less than 5 ºC, the compressor is stopped.
- Between 5 ºC-12 ºC, the compressor runs for 30 minutes and the defrost is stopped for
10 minutes.
- Between 12 ºC-16 ºC, the compressor runs for 45 minutes and the defrost is stopped
for 10 minutes.
3- When the room temperature is greater than 16°C, the temperature of the coil is detec-
ted, and the operation is performed according to the temperature of the coil, as follows:
- When the compressor is running for 30 minutes, the coil temperature is detected. If the
coil temperature is ≤ 1°C, the defrosting is stopped for 10 minutes.
4- Compressor delay protection:
- Every time the boot compressor is allowed to start immediately.
- After the compressor is shut down, start it again, with at least a 3 minutes interval.
Draining the collected water
When the water tank is full, the water tank full indicator light will turn on, the device will
stop automatically, and the buzzer will beep 15 times to alert the user that the water
needs to be emptied.
To drain the water, lightly press on the sides of the water tank with both hands and pull it