Installation Instructions – LD4/LD6 Commercial Recessed LED Rough-In
INSTALLATION
Rough-In Section Round
1.
Fixture Attachment Method: Install fixture into ceiling
cavity using 1/2˝ electrical conduit. Use 3/4˝ channel,
1-1/2˝ channel, 1/8˝ x 1/2˝ bar stock, or T-bar fasteners
as mounting rails (furnished by others) by inserting the
through hanger brackets at both sides.
2.
Hanger Adjustment Screw: Adjust hanger adjustment
screws (Figure 1.) so bottom of plaster ring is flush
with finished ceiling line. (Figure 2.) Hanger bracket is
reversible for total adjustment of 5˝.
3.
Remove one of the junction box covers. Connect supply
lead wires to lead wires of driver as per Wiring Diagram
and in accordance with your local electrical code(s) or
N.E.C. (Figure 27).
Hanger Bracket
Hanger
Adjustment
Screw
Figure 1
Figure 2
Rough-In Section Square
1.
Install fixture into ceiling cavity using 1/2˝ electrical
conduit. Use 3/4˝ channel, 1-1/2˝ channel, 1/8˝ x 1/2˝
bar stock, or T-bar fasteners as mounting rails (furnished
by others) by inserting the through hanger brackets at
both sides.
2.
Adjust hanger adjustment screws (Figure 3) so bottom
of square neck is flush with finished ceiling line. (Figure
2
Installation Instructions – LD4/LD6 Commercial Recessed LED Rough-In www.cooperlighting.com
Junction Box Covers
Trim
Assembly
Luminaire
Quick
Disconnect
4.) Hanger bracket is reversible for total adjustment of
5˝.
3.
(Height): Square neck can also be adjusted by loosening
the 3 thumbscrews and adjusting such that the neck is
flush with the ceiling. Once desired height is achieved,
tighten thumb screws (Figure 3).
4.
(Rotation): If rotation of the square neck is required,
loosen 2 thumbscrews. Rotate the square neck to
the desired position. Tighten thumbscrews upon
completion (Figure 3).
5.
Remove one of the junction box covers. Connect supply
lead wires to lead wires of driver as per Wiring Diagram
and in accordance with your local electrical code(s) or
N.E.C. (Figure 27
Height Adjustment
Thumb Screw
Rotational
Adjustment Thumb
Screws
Figure 3
Square Neck
Figure 4
Trim Installation
1.
Place end of flexible conduit through frame opening in
ceiling exposing upper portion of quick disconnect
2.
Remove LED engine from protective packaging.
3.
Remove trim assembly from protective packaging and
rotate side clips (3) outwards. (Figure 7).
4.
Figure 5 & 6 Representing single LED module and
Medium Distribution Trim
Luminaire
Quick
Disconnect
Junction Box

Publicidad

loading

Este manual también es adecuado para:

Ld6