Descargar Imprimir esta página

Cooper Lighting Solutions LD4 Instrucciones De Instalación página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions – LD4/LD6 Commercial Recessed LED Rough-In
Finished assembly
asymmetric film or
diffuser film
Figure 24
Cleaning
To Clean Trims:
1.
Press in on white plastic latch to remove upper reflector
and clean lens. (Figure 25 & 26)
2.
Gently wipe with soft, clean, dry lint-free cloth to
remove dust.
3.
Wipe with mild detergent solution on a soft, clean cloth
to remove fingerprints and stains.
4.
Rinse with clean water and dry with soft, clean, dry lint
free cloth.
White
Plastic Latch
Figure 25
Figure 26
6
Installation Instructions – LD4/LD6 Commercial Recessed LED Rough-In www.cooperlighting.com
Upper Reflector
(discard for 2 or
3 LED modules
and Beam forming
Modules)
Lens (Discard lens
when used with
Beam forming
Modules)
Figure 27
Electrical Connection
CAUTION
Make certain no bare wires are exposed outside of wire nut
connectors.
1.
Provide electrical service according to the "National
Electrical Code" or your local electrical code to the
junction box (located on the plaster frame). Supply wire
insulation must be rated for at least 90°C. The junction
box is listed for (4) #12 AWG (two in, two out) 90°C
conductors and feed thru branch wiring for type IC and
Plug in drivers for 120/277V only. For all other cases (8)
#12 AWG (four in, four out) 90°C conductors and feed
thru branch wiring for 120/277V only.
2.
Remove junction box cover (Figure 27).
3.
Remove appropriate round pry out and connect conduit
to junction box with proper connector (not included).
4.
Connect supply lead wires to junction box lead wires
(line, neutral and ground) in the fixture using the
provided lever nut connectors. (Figure 27). Be careful
not to leave any bare conductors outside of the lever
nut connectors.
5.
Lift the orange tab on the lever nut to disengage the
wire and close to secure the wire in place. (Figure 29).
6.
Connect white to white, black to black, and green (from
electrical service) on the supply side to the bare copper
wire in the junction box. Place all excess wiring and
connections into the junction box and replace the cover.
Driver Replacement
CAUTION
To avoid possible electrical shock, be sure that the power is
turned off before installing or servicing this fixture.
• The driver should be replaced by a qualified electrician.
• The driver may be replaced either from below or above the
ceiling.