Maintenance
Rain gauge cleaning
Clean every 3 months. Rotate the funnel counterclockwise and lift to access the rain gauge mechanism. Wipe
with a damp cloth to remove dirt, debris, and insects. For insect problems, lightly spray with insecticide.
Solar radiation sensor and solar panel cleaning
Clean every 3 months with a damp cloth.
Battery replacement
Replace every 1−2 years. In harsh environments, check every 3 months. Batteries may leak when used
for too long.
When replacing batteries: Apply a corrosion inhibitor, available at most hardware stores, to the battery
terminals.
In snowy conditions
Spray the top of the weather station with anti-icing silicone spray to prevent snow accumulation.
Troubleshooting
Remote sensor does not connect with the console:
Press the reset button for 3 seconds using a paper clip.
Re-sync the console with the sensor.
Check the blinking LED next to the battery compartment.
If necessary, replace the batteries in the external sensor.
The temperature sensor shows too high a temperature during the day:
Make sure the sensor is not located too close to heat sources or obstacles such as buildings, sidewalks,
walls or air conditioners.
You can use the calibration feature to troubleshoot installation problems due to heat sources.
Relative pressure does not correspond to official data:
Check pressure calibration with an official weather station.
Rain gauge shows rain when there is none:
Make sure the sensor is installed firmly and level (refer to the bubble level readings).
Data isn't transferring to wunderground.com:
Make sure the password and station ID are correct.
Set the correct date, time, and time zone on your console.
Check your router's firewall settings (port 80).