Performance
Data Sheet
SmartWater Filtration System
t4SWF
Cartridge
This system
has been tested according
to NSF/ANSI 42/53 for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water
entering
the system
was reduced to a concentration
less than or equal to the permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered
usage)
Standard No. 42: Aesthetic Effects
USEPA
Influent
Effluent
Parameter
MCL
Challenge Concentration
Average
Maximum
Chlorine
-
2.0mg/L+ 10%
0.06mg/L
0.10mg/L
Particulate**
-
atleast10,000 particlesimL
408,333
670,000
Standard No. 53: Health Effects
Parameter
Turbiditg
Cgsts
Lead at pH 6.5
Lead at pH 8.5
Hercurg atpH 6.5
Hercurg at pH 8.5
Lindane
Atrazine
2,4-D
Toxaphene
Benzene
Carbofuran
P- Dichlorabenzene
Asbestos
% Reduction
Min. Required
Average
Minimum
Reduction
97%
95.1%
_>50%
95.5%
89.4%
_> 85%
USEPA
MCL
1 NTU***
99.95% Reduction
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
Influent
Challenge
Concentration
11+ 1 NTU***
Minimum 50,000 L
0.15 mg/L + 10%
0.15 mg/L + 10%
0.006 mg/L + 10%
0.006 mg/L + 10%
0.002 mg/L + 10%
0.009 mg/L + 10%
0.210 mg/L + 10%
0.015 mg/L + 10%
0.015 mg/L + 10%
0.080 mg/L + 10%
0.225 mg/L + 10%
107 to 108 fibers/L;fibers > !01Jmin length
Effluent
Average
Maximum
0.38NTU
0.5 NTU
< ! #/L
4 #/L
< ! ppb
< ! ppb
3.1ppb
9.0ppb
0.34ppb
0.7ppb
0.66ppb
1.5ppb
< 0.02ppb
< 0.02ppb
< 0.5ppb
< 0.5ppb
7.7ppb
35 ppb
< i ppb
< i ppb
< 0.5ppb
< 0.5ppb
< i ppb
< i ppb
< 0.5ppb
< 0.5ppb
< 0.!7 MF/L
< 0.!7 MF/L
% Reduction
Average
Minimum
96.5%
95.4%
> 99.99%
> 99.99%
99.3%
99.3%
98.0%
95.5%
94.0%
89.6%
88.4%
73.7%
> 99.0%
> 99.0%
> 93.9%
> 94.3%
96.0%
82.0%
> 92.9%
> 92.9%
> 96.8%
> 97.0%
> 98.7%
> 98.7%
> 99.7%
> 99.8%
> 99%
> 99%
* Tested using pressure of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° _+5°F (20 ° _+2.5°C)
** Measurement
in Particles/ml.
Particles used were 0.5-1 microns
*** NTU=Nephelometric
Turbiditg
Units
Operating
Specifications
[] Capacitg: certified for up to 300 gallons (1135 I);up to six months for models without a replacement filter indicator light;
up to one gear for models with a replacement filter indicator light
[] Pressure
requirement:
20-120
psi (1.4-8.2
bar),
non-shock
[] Temperature:
33-100%
(0.6-38°C)
[] Flow
rate:
0.9 gpm
(3.4 Ipm)
General
Installation/Operation/Maintenance
Requirements
[] Flush new cartridge at full flow for 5 minutes to purge out trapped air.
[] Replace cartridge when flow becomes too slow.
Max. Permissible
Product Water
Concentration
mg/L
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.04mg/L
0.075 mg/L
99%
Special
Notices
[] Installation instructions, parts and service availabilitg, and standard warrantg are included with the product when shipped.
[] This drinking
water
sgstem
must
be maintained
according
to manufacturer's
instructions,
including
replacement
of filter cartridges.
[] Do not use with
water
that
is
microbiologicallg
unsafe
or of unknown
qualitg without adequate
disinfection
before
or
after
the sgstem.
Sgstems
certified
for cgst reduction
mag
be used
on disinfected
water
that
mag
contain
filterable
cgsts.
[]The
contaminants
or other
substances
removed
or reduced
bg this water
treatment
sgstem
are not necessarilg
in gour water.
[] Check
for
compliance
with
the state
and local
laws
and
regulations.
[] Note
that while
the
testing was performed
under
standard
laboratorg conditions, actual performance
mag
varg.
Sgstems
must
be
installed
and
operated
in accordance
with
manufacturer's
recommended
procedures and guidelines.
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
Taste and Odor Reduction
Chlorine
Reduction
Mechanical
Filtration
Unit
Nominal
Particulate
Reduction,
Class I
Sgstem Tested and Certified bg NSF International against NSF/ANSI Standard 42 & 55 for the reduction of:
Standard No. 53: Health Effects
Chemical Unit
Lead, Hercurg and Atrazine ReductJon
Lindane, Toxaphene and 2,4-D Reduction
Benzene, Carbofuran and
P-Dichlorobenzene Reduction
Mechanical Filtration Unit
Turbiditg Reduction, Cgst Reduction,
Asbestos Reduction
Manufactured
for: General
Electric
Compang,
Louisville,
KY 40225
1.800.626.2002
/41