Descargar Imprimir esta página

GE Profile PIT23SGRCSV Manual Del Propietario E Instalación página 41

Lado a lado

Publicidad

Idiomas disponibles

Idiomas disponibles

Performance Data Sheet
SmartWaterFiltrationSystem
GWF/ HWF Cartridge
Thissystemhas been testedaccording to NSF/ANS142/53for reduction of the substanceslisted below.
The concentrationof the indicated substancesin water entering thesystem was reduced to a concentration
less than or equal to thepermissible limit for water leaving the system,as specified in NSF/ANS142/53.*
(100%safety factors built in for unmetered usage)
Parameter
( :hlorin(
T & ()
Partk:ulale**
Parameter
USEPA
MCL
Stmldard
No. 42: Aesthetic
Effects
]nfluent
Eftluent
Challenge
Concentration
Aver age
Maximtml
2.0 mgiI. + 10%
0.02 ppm
0.05 ppm
at least 10,000 particles/mE
3,978
7,800
% Reduction
Average
Mhfimum
98.90%
97.37!'{
98.00!'_
96.10%
Stmadard
No. 53: Health
Effects
hd]uent
Eftluent
Min. Required
Reduction
> 50%
>85%
USEPA
MCL
1 NTI **'::
{){).95%Reduction
15 ppl)
15 ppl)
0.0002 lq)m
0.003 ppm
0.100 ppm
99%
ChMlel_e
Conceaaration
Average
Maximum
Aver age
'Ihrbidity
11 + 1 NT[ *'::*
0.07 NTI
0.1 NT[
99.71%
C>,ts
Minimum 50,000 L
26
55
99.97!_
Lead aI pII 6.5
0.15 mgiL + 10!:i
1 ppb
1 ppb
99.37%
Lead al pII 8.5
0.15 mgiL + 10{:i
1.8 ppb
4.3 ppb
98.8%
Lindane
0.t,q)2 mgiL + 10{:{
0.00005 ppm
0.00005 ppm
91.93%
Atl-4zine
0.t,q)9 mgiL + 10{:{
0.t,q)2 ppm
0.003 ppm
76.1{t%
2,4-I)
0.210 mgiL + 10{:{
0.042 ppm
0.090 ppm
84.8{t%
zYs/)estos
107 to I(Y tibep_iL;
t).32 MFLiml
1.2 MFI.iml
99.95{_
fibel'_ gwater tllan
10 micrometel'_
in length
% Reduction
Mhmnum
99.59!_
99.95%
99.37%
97.13%
91.93!_
64.28!_
67.63!_
99.82%
Min. Required
Reduction
0.5 NT[ 7
> 99.95%
0.010 mg/L
0.010 mgiL
0.0002 mg!L
0.0',)3 mgiL
0.07 mgiI.
99%
* Tested using a flow ra te of O. 5 gpm; pressure of 60 psig; pH of 7.5 _+O. 5 ; temp. of 20 ° _+ 2,5°C
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating Specifications
(_apacitv:
certified
for
up to 300 gallons
(l 135 1); up to six months
tot
models
without
a replacement
filter
indicator
light;
up
to one
vear
for
models
with
a replacement
filter
indicator
light
Pressttre
requirement:
40-120
psi
(2.8-8.2
bar),
non-shock
Temperature:
33-100°F
(0.6-38°C)
Flow
rate:
0.5 gpm
(1.9
lpm)
General InstallationlOperation/Maintenance
Requirements
Flush
new
cartridge
at full flow
for
.3 minutes
to Imrge,
out
trapped
air.
Replace
cartridge
when
flow becolnes
too
slow.
Special Notices
li_stallation
ii_sti uctions,
parts
and
service
availability,
and
standard
warranty
are
inchtded
with
the
product
when
shii)ped.
This
driI_king
water
sx:steln
Inust
be
inaintained
according
to inanufacturer's
instluctions,
inchtdii_g
replacen/ent
of filter
ca rtridges.
Do
not
use
with
water
that
is inicrobiologically
tmsali _ or of tu_klmwn
quali W without
adequate
disinfection
before
or
after
the
svsteln.
Svstelns
certified
for
cyst reductiola
inav
be
used
on disinfected
water
that
inav
contain
filterable
cysts.
The
contanfilmlatS
or other
substances
relnoved
or reduced
by this
water
treatlnelat
s_steln
are
not
necessarily
in your
water.
Check
ti)r
compliance
with
the
state
and
local
laws and
regulations.
Note
that
while
the
testing
was performed
trader
standard
laboratory
conditions,
actual
performance
may
vary.
Systems
Inust
be installed
and
operated
ill accordance
with
inanutacturer's
reconllnended
procedures
and
guidelines.
System Tested and Certili(d
by NSF Int( rnational
against ANSI/NSF
Standard
42 & 53 t)n-
I1:1(: r((lt/(:tioll
of:
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
'Ihst_ and ()dot
Reduction
Chlorine
Reduction
Mechanical
Fihration
Lnit
Particular(
Reduction,
Class I
Standard
No. 53: Heahh
Effects
Chemical
Re(luction/nit
I.ead
and
Atrazine
Reduction
Lindane
and
2,4-1)
Reduction
Mechanical
Fihration
Unit
Ttwbi(litv
Reduction
Cyst and
Asbestos
Reduction
Mantd'actured
tk)r: (;( neral
Electri(
(_oml)any,
I.ouisville,
KY 40225
4/

Publicidad

loading