Fuse Check/Replacement/Reset - Nilfisk-Advance Terra 4300B Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FUSE CHECK/REPLACEMENT/RESET

1.
Drive the machine on a level fl oor and engage the parking
brake with the pedal (3) and the lever (4).
2.
Turn the ignition key (72) to "0".
3.
Open the hood (7).
4.
Disconnect the battery connector (46).
Lamellar fuse check/replacement
5.
Remove the fuse box cover (51).
6.
Check/replace the relevant fuse among the following (Fig.
19):
F1:
Main fuse (key circuit) (15 A)
F2:
Filter shaker motor fuse (25 A)
F3:
Manual vacuum system fuse (40 A) (optional)
F4:
Vacuum system motor fuse (30 A)
F5:
Horn and pivoting light fuse (10 A)
F6:
Working light fuse (10 A) (optional)
7.
Remove the electrical component box cover (55).
8.
Check/replace the following fuse (Fig. 20):
FT:
Drive system fuse (70 A)
Circuit breaker check
9.
Check for deactivation of one of the following fuses, then
reset it after the relevant motor has cooled down:
FA:
Main broom motor circuit breaker (30 A) (52)
FB:
Side broom motor circuit breaker (10 A) (53)
Assembly
10.
Assemble the components in the reverse order of
disassembly.
INSTRUCTIONS FOR USE
F1 F2
Terra™ 4300B
146 2810 000(2)2008-07
ENGLISH
F4
F6
F7
F3
F5
Figure 19
Figure 20
F8
S311413
FT
S311414
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

908 4309 010

Tabla de contenido