4.4 SELECTING OPERATOR PREFERENCES

4.4.1 FINE BALANCING MODE

This balancer measures with the maximum precision
availa ble all the time, 1g / 0.05 oz, however values
below 5g / 0.25 oz are shown as zero while in the
normal operating mode. Values exceeding 5g / 0.25 oz
are rounded to the amount of the nearest commercial
wheel weight.
Press the FINE button to advance to the display
resolution between 5g / 0.25 oz and 1g / 0.05 oz.

4.4.2 OUNCE/GRAMS CONVERSION

When the machine is fi rst turned on it is preset to display
the imbalance in ounces.
Press the MODE button to advance to select ounces
or grams.
Select Enter to save selection.

4.4.3 RIM DIAMETER IN MILLIMETERS

The rim diameter is normally displayed in inches,
however if the value in millimeters is desired. Press
the MODE button until "PAX/mm" is NOT illuminated
to display in inches, when lit the unit displays in mm.
W
Figure 23
16

4.5 ENTER RIM PARAMETERS

4.5.1 Rim Distance and Diameter (offset)

- Move the rim offset arm to the edge of the rim, touch
the pointer to the rim edge as illustrated in Figure 23a
and hold steady for about a second. The beeper will
sound when the distance and diameter values are cal-
culated and entered. Return the arm to its fully in and
down position on the balancer. Do not allow the mea-
surement arm to "dangle" down in front of the balance.
Figure 23a

4.5.2 Measure/Enter rim width (manual)

using rim width calipers.
Measure wheel where corrective clip-on weight would
be applied, Figure 23b. Press the Width entry key,
Figure 23-W, and enter the measured width by pressing
+/- keys until the desired value appears in the display.
Figure 23b