Thank you for buying this product. Our company is sure that you
will be more than satisfied with the performance of the product. This
product is supplied with a "WARNINGS" leaflet and an "INSTRUC-
TION MANUAL". These should both be read carefully as they
provide important information about safety, installation, operation
and maintenance. This product complies with recognised technical
standards and safety regulations. We declare that this product is in
conformity with the following European Directives: 2004/108/CEE,
2006/95/EEC, 98/37/EEC and subsequent amendments.
1) GENERAL OUTLINE
Compact electromechanical barrier suitable for limiting private areas,
parkings, access areas for vehicles only. Available for passageways
from 3 to 5 metres. Adjustable electromechanical limit devices ensur-
ing a correct stop position for the boom. In case of intensive use, a
thermal sensor activates the cooling fan.
The emergency release device for manual manoeuvre is controlled
by a personalised key lock.
The actuator is always supplied for left-hand side fitting.However,
when necessary, the opening direction can be reversed by means
of simple operations.
The CBO mod. foundation base (on request) makes barrier instal-
lation easier.
Appropriate fittings make it easy to install accessories without need-
ing to drill any holes.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the
product can cause damage to persons, animals or things.
• The "Warnings" leaflet and "Instruction booklet" supplied with
this product should be read carefully as they provide important
information about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc)
according to the provisions set out by current standards. Keep
nylon or polystyrene bags out of children's reach.
• Keep the instructions together with the technical brochure for
future reference.
• This product was exclusively designed and manufactured for the
use specified in the present documentation. Any other use not
specified in this documentation could damage the product and
be dangerous.
• The Company declines all responsibility for any consequences
resulting from improper use of the product, or use which is different
from that expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with
the following European Directives: 2004/108/CEE, 2006/95/EEC,
98/37/EEC and subsequent amendments. As for all non-EEC
countries, the above-mentioned standards as well as the cur-
rent national standards should be respected in order to achieve
a good safety level.
• The Company declines all responsibility for any consequences
resulting from failure to observe Good Technical Practice when
constructing closing structures (door, gates etc.), as well as from
any deformation which might occur during use.
• The installation must comply with the provisions set out by the
following European Directives: 2004/108/CEE, 2006/95/EEC,
98/37/EEC and subsequent amendments.
• Disconnect the electrical power supply before carrying out any work
on the installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power
supply, having a contact opening distance equal to or greater
than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted
just before the power supply mains.
• Check that earthing is carried out correctly: connect all metal
parts for closure (doors, gates etc.) and all system components
provided with an earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
INSTALLATION MANUAL
conveying and shearing, according to and in compliance with the
applicable directives and technical standards.
• Position at least one luminous signal indication device (blinker) where
it can be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the auto-
mation safety and correct operation when other manufacturers'
components are used.
• Only use original parts for any maintenance or repair opera-
tion.
• Do not modify the automation components, unless explicitly
authorised by the company.
• Instruct the product user about the control systems provided and
the manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation
operation area.
• Keep radio control or other control devices out of children's reach,
in order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on
the automation system, and always request the assistance of
qualified personnel.
• Anything which is not expressly provided for in the present instruc-
tions, is not allowed.
• Installation must be carried out using the safety devices and
controls prescribed by the EN 12978 Standard.
3) TECHNICAL SPECIFICATIONS
MOOVI 30-50
Power supply: ................................................230V~±10% 50Hz (*)
Absorbed power: ................................................................... 300W
Motor: ............................................................... 1400 min
Capacitor: .............................8µF 450V (230V) :32µF 250V (110V)
Absorption: ................................................................... 0.8 A :1.6 A
Insulation class: ............................................................................ F
Ventilation intervention temperature: ..................... 110°C (winding)
Circuit-breaker intervention temperature: ..... 130°C (self-resetting)
Reduction gear lubrication: ................................Permanent grease
Max torque:..........................MOOVI-30 85Nm: MOOVI-50 250Nm
Opening time: .................................. MOOVI-30 4s : MOOVI-50 8s
(Aluminium) bar length: MOOVI-30 3m max : MOOVI-50 5m max.
Impact reaction (electric edge): ............... Stop or stop and reverse
Limiting devices: ................... Electric, incorporated and adjustable
Manual manoeuvre: ............................................Quick key release
No. manoeuvres in 24 hour: .. 1200 (MOOVI-30) :600 (MOOVI-50)
Working temperature: .............................................. -10°C ÷ +55°C
Degree of protection: ............................................................... IP24
Actuator weight (without bar): ............................... 356N (~35.6 kg)
Dimensions: ...................................................................... See fig.1
ALPHA BOM CONTROL PANEL
Power supply: ...............................................230V~±10% 50Hz (*)
Loadless absorption: ......................................................... 100 mA
Accessory output power: ..................................24V~ 200 mA max
Max. motor power absorbed: ................................................ 500W
Limits switch: ............................................................ electric switch
Working time: ...................................................................10 s MAX
Working temperature: ................................................... -10 +55 °C
(*) Special power voltages available on request.
4) OPTIONAL ACCESSORIES (Fig.17)
- CBO. Foundation base
- MOOVI PRM. Antishearing Kit
- MOOVI 130. Kit for Cellula 130 fixing post
- FAF. Fixed fork for boom rest
- MOOVI GA. Movable rod for boom rest (Only for MOOVI 50)
- MOOVI GAMA. Movable cushioned rod for boom rest
- SB. Skirt already assembled to the boom
- Safety edge BIR
- MOOVI LIGHT. Light kit for booms from 3m to 4.5m
- MOOVI LIGHT 1. Light kit for booms from 5m to 6m
- MOOVI PCA. Lower or upper boom covering contour
ENGLISH
MOOVI 30-50 - ALPHA BOM Ver. 05 -
, 4 poles
-1
15