2.6 Zoom
The group windows can be scaled. The main mixer, the scene desk, the sequence tables, and the trackball
areas cannot be scaled.
2.7 Control of functions of the programme by shortcut
2.7.1 Direct value input for individual channels:
Mark the corresponding fader by mouse or by TAB key and shortly press the keys 'CTRL' + 'SHIFT' at the
same time. It is now possible to directly enter the DMX value (0-255) in the input window and confirm with
'OK' or the 'ENTER' key.
2.7.2 Fader control by keyboard:
Select the fader of the desired channel with the TAB key and increase the DMX value with the arrow keys
'left' or 'above' or reduce it with 'right' or 'below'. The key 'Page up' increments the value by 10, the key 'Page
down' decrements the value by 10. The value 255 is adjusted with the key 'POS 1' and the value 0 with the
key 'End'.
2.7.3 Calling scenes via the keyboard:
Press the key 's' and enter the desired scene number. Confirm with 'OK' or 'ENTER'.
2.7.4 Placing scenes on function keys and calling them:
It is possible to place up to 120 scenes on the function keys F1 to F12. Call a level with 12 function keys with
the numerical keys (the block of numbers on the right of the keyboard). 10 levels are available. After pressing
the '0', the first level with the functions 1 to 12 is active. After pressing the '1', the second level with the
functions 13 to 24 is active, after pressing the '9' the tenth level with the functions 109 to 120. A function key
of a level is reserved with a scene by pressing the key 'SHIFT' and the desired function key at the same time,
e.g.: First select level 2 with the numerical key '1'. Then open the window for the function keys with 'SHIFT'
and 'F5' for function 17 and as an example enter the scene 117 . Confirm with 'OK' or 'ENTER'. A scene
saved on the function keys is called accordingly. In our example of scene 117: First press the '1' on the
numerical block for level 2. Then press 'F5' and the scene 117 is called.
(see also item 2.2.4 The function key table)
2.7.5 Starting and stopping the sequences via keyboard:
Created and loaded sequences in the sequence tables A to D can be started and stopped by pressing the key 'q'
and the numbers 1 to 4 or the letters a to d.
2.7.6 Starting and stopping macros via keyboard:
To start a macro via keyboard, actuate the key 'm'. Then the number of the macro has to be entered. It is
required that the macro (macro number) has already been created. A current macro can be stopped with the
same shortcut.
3 Specifications
Specifications of the converter box:
- Processor-controlled converter for 510 DMX channels
- Connections: