OBJ_BUCH-2159-003.book Page 8 Monday, August 25, 2014 9:53 AM
8 | English
Operation
Starting Operation
Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging process begins as soon as the mains plug of the
charger is plugged into the socket outlet and the inductive
battery 1 or the power tool with battery 1 (with base of the
battery) is placed onto the charging platform 5.
The charging process only begins when the battery capacity is
less than 85 – 90 %. This prolongs the life of the battery.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Meaning of the Indication Elements
Continuous Light Standby Indicator (green) 2
The continuous light of the green standby indica-
tor 2 shows that the mains plug has been plugged
into the socket outlet and the charger is ready for
use.
Flashing Charge Status Indicator 3
The fast charging process is indicated by
the flashing of the respective green LED of
the charge status indicator 3. When the re-
spective share of the battery is charged, the
green flashing light changes to a green continuous light.
The battery can be removed at any time and used. When all
five LEDs indicate a green continuous light, the battery is fully
charged.
Continuous Light Error Indicator (red) 4
The continuous light of the red error indicator 4
shows that the temperature of the battery is out-
side of the permitted charging temperature range,
see section "Technical Data". As soon as the per-
mitted temperature range is reached, the charger automati-
cally switches to fast charging.
Flashing Error Indicator (red) 4
The flashing light of the red error indicator 4 sig-
nals a different fault of the charger, see section
"Troubleshooting – Causes and Corrective Meas-
ures".
1 609 92A 0HX | (25.8.14)
Troubleshooting – Causes and Corrective
Measures
Cause
Corrective Measure
Red error indicator 4 flashes
No charging procedure possible
The battery is not positioned
Position the battery centrally
(correctly)
with the battery base on the
charging platform 5
Detection of foreign object
Remove object
An object other than/in addi-
tion to the battery is on the
charging platform
Wrong battery positioned
Position a compatible battery
Battery pack defective
Replace the battery
Standby indicator (green) 2 does not illuminate
Mains plug of battery charger
Insert mains plug (fully) into
not plugged in (properly)
the socket outlet
Socket outlet, mains cable or
Check the mains voltage;
battery charger defective
have the battery charger
checked by an authorised af-
ter-sales service agent for
Bosch power tools
Working Advice
With continuous or several repetitive charging cycles without
interruption, the charger can warm up. This is not meaningful
and does not indicate a technical defect of the battery charg-
er.
A significantly reduced working period after charging indi-
cates that the battery is used and must be replaced.
Maintenance and Service
After-sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
Bosch's application service team will gladly answer questions
concerning our products and their accessories.
In all correspondence and spare parts orders, please always
include the 10-digit article number on the type plate of the
battery charger.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Bosch Power Tools